Product Manual

Sump Pumps
Instruction Manual &
Safety Warnings
Models S3033, S3050, S3100
Important Safety Instructions
SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and OPERATING
INSTRUCTIONS. You will need to refer to it before attempting any installation or maintenance.
ALWAYS keep these instructions with the unit so that they will be easily accessible.
Failure to read and follow these warnings and instructions could result in property damage,
serious injury, or death.
ALWAYS disconnect the pump and float switch controller from the power source before servicing
or making adjustments.
NEVER handle the pump or motor with wet hands or when standing on a wet or damp surface
while the pump is plugged into the power source.
MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is wired with
a 3-prong grounded plug. To reduce the risk of electric shock, be certain that it is only connected
to a properly grounded, 3-prong receptacle. If you have a 2-prong receptacle, have a licensed
electrician replace it with a 3-prong receptacle according to local codes and ordinances.
NEVER bypass grounding wires or remove the ground prong from the plug.
DO NOT use an extension cord. The electrical outlet should be within the length of the pump’s
power cord, and at least 4 feet above the floor level to minimize potential hazards from flood
conditions.
DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking
the cord.
MAKE SURE the supply circuit has a dedicated fuse or circuit breaker rated to handle the power
requirements noted on the nameplate of the pump.
DO NOT use the power cord or strain relief to carry the pump. Use the pump handle.
DO NOT pull on the float switch cord.
DO NOT expose the control unit to any type of moisture, water, rain or snow.
DO NOT place the controller on the floor. The electrical outlet should be within the length of the
pump’s power cord and at least 4 ft above the floor.
DO NOT operate this product if it has been damaged in any way.
DO NOT use sump pumps in pits handling raw sewage, salt water, or hazardous liquids. This pump
is for ground water only.
DO NOT disassemble this product. When service is required, contact Glentronics technical support
at 800-991-0466. Return the product to the manufacturer for any repairs at the following address:
Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069
When installing or replacing a primary sump pump you should also install a battery backup sump
pump system.
! WARNING
Risk of electric shock. To reduce this risk, observe the
following precautions.
! CAUTION
To reduce the risk of hazards that can cause injury or property
damage, observe the following precautions.
Specifications 1/3 HP Model S3033 1/2 HP Model S3050 1 HP Model S3100
GPH @ 0’ 3900 4380 5940
GPH @ 10’ 3000 3900 5520
Pump diameter 7.9” 8.5” 11”
Volts 115V, 60Hz 115V, 60Hz 115V, 60Hz
Amps 4.0 4.3 11.5
Items Included:
Pump
Choice of controller, float
Stainless steel hose clamp
2" x 1-1/2" reducer adapter
(on 1/2 HP and 1 HP pumps only)
Note: The 1/2 HP and 1 HP pumps
will accommodate a 2" discharge
pipe. However, most homes have
1-1/2" pipes. Therefore we have
included a 2" x 1-1/2" reducer
adapter with this pump. You may
replace your 1-1/2" discharge pipe
with a 2" discharge pipe, and a 2"
adapter to obtain the optimum
gallons per hour.
Dual Float
Controller
Enhanced
Controller
Deluxe
Controller
Dual Float
Switch
Vertical Float
Switch
Tether Float
Switch
You may also need:
1-1/2” rigid PVC pipe to connect
to the existing plumbing
A check valve or union
PVC pipe cleaner
and cement