Warranty

Item # DRNAGS Drain Cleaner Manual
5
TROUBLESHOOTING
Cable kinking or breaking
Cable is being forced.
Cable used in incorrect pipe diameter.
Motor switched to reverse.
Cable exposed to acid.
Cable worn out.
Cable not properly supported.
Do Not Force Cable! Let the cutter do the
work.
Use correct cable/equipment.
Use reverse only if cable gets caught in
pipe.
Clean cables routinely.
If cable is worn, replace it.
Support cable properly, see instructions.
AUTOFEED doesn’t work.
AUTOFEED full of debris.
AUTOFEED needs lubrication.
Clean AUTOFEED.
Lubricate AUTOFEED
Machine wobbles or vibrates while
cleaning drain.
Cable not evenly distributed.
Pull cable out and re-feed in, evenly
distribute.