User`s guide

3.2.3 Security Levels
3.2.2 What are Parameters
There are 5 security levels on the T-Max® Mgr/Pro. When the Menu
button is pressed, the display will prompt you for a security number. Refer
to the enclosed Security Number Sheet on how to change security numbers.
The description of these levels follows:
Parameters are values stored in each T-Max® 3As such as Lamp Hours,
Session Counts, etc. Table 1 shows the parameter numbers and details
about them.
Level 0 - Computer Control Level
Sessions can be monitored, but not started manually.
To get or change parameters, do the following:
Level 1 - Employee Level
1)
Press the BED NUMBER
you want to check or change, followed by the
ENTER key. The bed number and its status will appear.
Session operation only. No parameters can be observed or changed.
Level 2 - Supervisor Level
2)
Press the CALL/MENU button.
Parameters values can be observed but not changed.
3) The following message will appear: SECURITY#. Enter the security
number for level 3 followed by the ENTER key.
Level 3 - Manager Level
Parameters can be observed and changed. Security numbers cannot be
changed.
4) The following message will appear: GET PARAMS? Do you want to
see what is stored, or change it?
Level 4 - Owner Level
This level allows the changing of security numbers for access.
If you just want to see current values, press ENTER
Asterisks will be displayed on the lower left corner of the VFD indicating
which security number was last entered, a single asterisk for level 1, 2
asterisks for level 2 and 3 asterisks for level 3.
If you want to send new values, go to Step 6.
5) The following message will appear: WHICH PARAMETER? Enter the
parameter number from Table 1 followed by the ENTER key.
3.3 Starting A Session
The top line on the VFD display will show the bed number. The
second line will show the value for the parameter you checked.
You must be at Security Level 1, 2
or 3 to start sessions manually. If you
don’t have any asterisks in your VF
Display – you can’t send time from the
Manager.
Press CLEAR
to exit.
6) Press the NEXT button.
7)
The following message will appear: SEND PARAMS? Press the
ENTER
button.
8) The following message will appear: WHICH PARAMETER? Enter the
parameter number from Table 1 followed by the ENTER button.
9) The following message will appear: SEND WHAT DATA? Enter the
value that you want to store in that timer followed by the ENTER button.
Press CLEAR
to exit.
1) Press the BED NUMBER you want to start, followed by the ENTER
button.
2) Press the TIME button. The display will read “Enter Session Time”.
3) Enter the SESSION TIME you want followed by the ENTER button.
T-Max® Manager/Pro and T-Max® 3A User’s Guide Page 11 T-Max® Manager/Pro and T-Max® 3A User’s Guide Page 12