User`s guide
This number must be equal to or
higher than the highest address that a T-
Max® 3A is set. For example if you have six
beds, but are addressing the T-Max® 3As to
1,2,3,4,5, and 8, set the maximum bed
number to 8.
Table 1 - Parameter Numbers
Param
#
Description Max # Default Notes
1 Address 255 254 Address of T-Max® 3A
2 Beep Mode 1 0 Used for High Pressure beds. 0=Alarm only, 1=Alarm
and Flip
3 Delay Time 10 0 Delay in minutes stored in the T-Max® 3A.
4 Current
Sense
1 0 For the T-Max® Sentry™ Option. 0=Disabled,
1=Enabled.
5 Session
Counts
65535 0 Total session counts for T-Max® 3As.
6 Lamp Hours 65535 0 Bulb hours for each bed.
7 Bed Hours 65535 0 Number of hours a bed is on.
8 Manual
Session
Counts
65535 0 Counts the number of sessions the T-Max® 3A has
run while in Stand Alone Mode
9 Clean Room 1 1 0 = Clean Room Disabled, 1 = Enabled
10* Manual
Lockout
1 0 0 = Stand Alone Enabled, 1 = Disabled
13 Cool Down
Mode
10 0 0 = Disabled, 1-10=Enabled. Time delay in minutes
allowing bed to cool.
15 Fixed
Session
Counts
65535 0 Counts number of sessions ran through the T-Max®
3A. This value cannot be changed at all. Used as
point of reference.
17 Clean Clear 1 0 0 = Press and hold the Up button for 3-4 seconds to
clear the clean room. 1 = Press and release the Up
button to clear instantly.
18 Redisplay 2 0 0 = After a session ends and the clean room is
cleared, the T-Max® 3A will show a 0. 1 = After
session ends and the clean room is cleared, the T-
Max® 3A will show the last session time entered. 2-
10 = After the session ends and the clean room is
cleared, the max. time will show on the T-Max® 3A.
20 External
Speaker
1 0 0 = Speaker on T-Max® 3A, 1 = External Speaker
will be used.
21 Pause Mode 1 0 0 = When session is paused, time will continue to
count down. 1 = When session is paused, session time
will stop counting down.
22 Auto Bed
Shut Off
1 0 For T-Max Intercom Systems Only. 0 = When timer
is called, bed will stay on, 1 = When timer is called,
bed will shut off automatically.
9)
The following message will appear: MANAGER NUM. If you are
using one Manager, press ENTER.
If you are using multiple Managers,
enter the T-Max® Mgr/Pro address, followed by the ENTER
button.
Up to 8 T-Max® Mgr/Pro’s can be connected in a single salon. One T-
Max® Mgr/Pro must be set to address 0. All slave T-Max® Mgr/Pro’s must
be set to an address other than 0. Set each Slave T-Max® Mgr/Pro to a
unique address.
10) The following message will appear: MGR RE-SCAN TIME. Press
the ENTER key (without entering a number).
11) The following message will appear: MAX SLAVE. If you are only
using one Manager, press ENTER (without entering a number). If you are
using multiple Managers press 7, then ENTER
.
The VFD display will then read SAVING PARAMS.
• If Manual Lockout is enabled, the T-Max® 3A cannot operate as a stand-alone
timer. In the event of a T-Max® Mgr/Pro failure, this parameter cannot be enabled
at the T-Max® 3A