5. Azimuth setting
The cartridge needle must be perpendicular to the record in order to trace the groove wall modulations
correctly.
The azimuth (angle) is precisely set by the factory. In the event that you need to modify this setting, however,
follow the instructions below.
Loosen the small azimuth screw, again using the 1.5 mm allen key.
DO NOT REMOVE THE AZIMUTH SET SCREW COMPLETELY!
Loosen the screw just enough to be able to gently rotate the arm tube and set the azimuth to the correct
position. The correct position can be checked from the front view, preferably with the needle placed on a
mirror placed on the platter. Once the azimuth setting is correct, gently re-tighten the azimuth setting screw.
ESSENTIAL III SPECIFIC INFORMATIONS
Controls, features and connections
1 ON/OFF SWITCH
2 STEPPED DRIVE PULLEY
3 OUTPUT CABLE CONNECT IT E
__________________________________________________________________________________________
Switching on and off
Pressing the ON/OFF switch alternately starts or stops the motor.
Changing replay speed