Specifications

8-6 EM-506 (N-07/03)
ETHERNET CONVENIENCE OUTLET
The Interface option for presence sensing device
includes pedestal mounting of the standard palmbutton
operator station and mute indicator light. When the red
GUARD OFF lights are illuminated, the presence
sensing device is muted. See Figure 8-10.
This connector on the side of the electrical enclosure is
available to allow easy connection of an Ethernet cable
to add the PROFORM PC Control to a network without
special wiring into the electrical enclosure.
Some presence sensing devices are programmable and
allow a blanking window of variable size to be
programmed from step-to-step. The PROFORM has an
output available that can be configured as a step advance
output to a programmable presence sensing device to
take advantage of this feature.
FIGURE 8-11 Ethernet Convenience Outlet
OIL COOLER
The optional oil cooler is an air-type heat exchanger. See
Figure 9-13. The heat exchanger is equipped with a
thermostatically controlled electric fan, which is
operable only when the motor/pump is running. The
thermostat is set to start the heat exchanger motor at
approximately 135
°F.
OIL HEATERS
Oil heaters are recommended for cold start-ups and cold
running conditions. They are immersion-type and are
thermostatically controlled. It will only maintain the oil
temperature in the tank to permit machine start-up, they
are not for heating up the oil. The thermostat is set to
start the heater if the temperature falls below
approximately 60
°F.
FIGURE 8-10 Mute Indicator Light for Presence Sensing
Device
PROGRAMMABLE FOOTSWITCH
The Programmable Footswitch feature is used to select
which footswitch must be pressed to cycle the ram when
two or more footswitches are installed and turned on
(active).
OIL LEVEL/TEMPERATURE SWITCH
If the oil drops to the minimum allowable level, an error
message appears on the touchscreen display. Stop
machine operation as soon as possible. The cause for the
low oil level should be found and corrected. Fill
reservoir to the proper level.
As opposed to selecting multiple footswitches in the
Operator Stations dialog, the Programmable Footswitch
option makes footswitch selection step-wise
programmable. Any combination of footswitches may be
selected for each step. See EM-508, SECTION 7,
“SOFTWARE - RAM PAGE, PROGRAMMABLE
FOOTSWITCH” for details on use and programming.
If the operating temperature reaches the maximum level,
an error message appears on the touchscreen display.
Stop machine operation as soon as possible and locate
the cause of the excessive heat. Excessive high
temperature will cause the main drive to shut down.