User manual

Chapter 2 Hardware Installation
2-13
Create a Panel Cut
Create a panel cut for the PS-A, like that pictured here. Two additional items, the installation gasket and the
installation fasteners are required when installing the PS-A.
PS-A Viewing Angle
Be sure that the panel’s viewing angle is tilted no more than 30 degrees from parallel to the operator (i.e.
operator is directly in front).
Avoid placing the PS-A next to other devices that might cause overheating.
Avoid using the PS-A where the ambient temperature will be higher than the allowed specification.
Keep the PS-A away from arc-generating devices such as magnetic switches and non-fuse breakers.
Avoid using the PS-A in environments where corrosive gases are present.
SEE
1.5.3 Panel Cut Dimensions (page1-13)
To obtain the maximum degree of moisture resistance, be sure to install the PS-A on a smooth,
flat surface.
The panel itself can be from 1.6 mm [0.06 in] to 10.0 mm [0.39 in] thick
Strengthening may be required for the panel. Be sure to consider the weight of
the PS-A when designing the panel.
Panel
Panel Cut
1.6 mm [0.06 in] - 10.0mm [0.39 in]
Must be 30 degrees or less
OK
OK
OK