Installation guide
E-3
• The environment specifications given here are for a PSA-HD20
installed in a PS-A unit.
• Pro-face does not guarantee the preservation of any data stored on
the PSA-HD20 if the HDD unit has an accident, malfunctions or is
damaged in any way. Therefore, the regular backing up of important
HDD data to either a floppy disk, or other type of suitable magnetic
media is strongly recommended.
• The PSA-HD20 has a finite usage lifetime. The lifetime figure given in
this document is for reference, and the periodic replacement of the
current HDD unit with a new HDD unit is strongly advised.
• Using the PSA-HD20 in an environment that is excessively hot and/or
humid will shorten the disk’s usage lifetime. A wet bulb temperature of
29
o
C or less is recommended. This is equivalent to the following data.
• In order to extend the lifetime of the hard disk, Pro-face recommends
you set the Windows [Control panel]-[Power Management option]-
[Turn off hard disks] selection to turn the hard disk off when the unit is
not being operated. A setting of 5 minutes is recommended.
Environment
Temperature Humidity
at 35
o
C
no higher than 64%
at 40
o
C
no higher than 44%
PS-3700A
+5
o
C to +50
o
C
PS-3701A
+5
o
C to +45
o
C
-10
o
C to +60
o
C
10%RH to 85%RH
(no condensation)
(Wet bulb temperature: 29
o
C or less)
Noise Voltage: 1500Vp-p
Pulse Width: 50ns, 500ns, 1
µ
s
4kV
4.9m/s
2
(10Hz to 25Hz) (When Operating)
3920m/s
2
(1ms, Half-sine shock pulse)(When Operating)
Electrostatic Discharge Immunity
Vibration Resistance
Shock Resistance
Operating Temperature
Storage Temperature
Ambient Humidity
Noise Resistance
(via Noise Simulator)