Wiring
To avoid an electric shock, prior to connecting the PL unit’s power cord terminals to the
power terminal block, confirm that the PL unit’s power supply is completely turned OFF, via
a breaker, or similar unit.
Supplying a power voltage other than that specified will damage the power source and the
PL unit.
When the FG terminal is connected, be sure the wire is grounded.
Connect the power cord to the Power Connector using the Power Plug on the Rear of the PL
unit.
Power Cord Specifications
Use copper conductors only.
*1 If the Conductor
s end (individual) wires are not twisted correctly, the end
wires may either short against each other, or against an electrode.
Wiring
When connecting the Power Cord, use the following items when performing wiring. (Items
are made by Phoenix Contact.)
Wiring
1 Wiring for the PL unit
Power Cord Diameter
0.75mm
2
to 2.5mm
2
(18AWG to 12 AWG)
Conductor Type Simple or Twisted Wire
*1
Conductor Length
Recommended Driver SZS 0.6X3.5 (1205053)
Recommended Pin Terminals
AI 0.75-10GY(3201288)
AI 1-10RD(3200182)
AI 1.5-10BK(3200195)
AI 2.5-12BU(3200962)
Recommended Pin Terminal Crimp Tool CRIMPFOX ZA3 (1201882)
10mm[0.39in.]