Specifications

15
The PL unit is designed to be installed in a Panel. Refer to the following procedure to mount
the PL unit.
(1) Create a Panel Cut on the Panel surface as shown in the panel cut dimensions
illustration.
(2) Confirm that the installation gasket is attached to the PL unit and then place the PL unit
into the Panel from the front.
(3) Insert the hook of the installation fastener into twelve(12) insertion slots of the PL unit
and tighten the back of the installation fastener using a screwdriver. For the position of
the insertion slot, refer to the dimension illustration.
2 Installing the PL unit in a Panel
It is strongly recommended that you use the installation gasket, since it
absorbs vibration in addition to repelling water.
SEE
For the procedure for replacing the installation gasket, refer to “PL-6930/
PL-7930 Series User Manual”.
Tightening the screws with too much force can damage the PL unit’s
plastic case.
The torque required to tighten these screws is 0.5 Nm.
Lower 4-R3
Panel Thickness
1.6[0.06]~10.0[0.39]
Unit: mm[in.]
360.0
+0.5
-0
311.0
+0.5
-0
[14.17 ]
+0.02
-0
+0.02
[12.24 ]
-0
Panel
Installation Fastener
PL