Specifications

Chapter 4 Installation and Wiring
4-9
Connecting the Power Cord
(1) Confirm that the power cord is unplugged from the power supply.
(2) Open the cable attachment holes of the Power Plug. There are Open Buttons next to the holes corre-
sponding to each of cable cores. Push that button with a straight slot screwdriver etc., and the button
opens.
(3) Insert the crimp-type pin terminal of the cable core completely into the hole with the Open Button
pushed. When stopping pushing the button, the hole shuts and the cable is fixed.
(4) Insert the power plug into the socket of the PL, then screw both of the minus (-) screws to fix. The torque
required to tighten these screws is 0.5Nm to 0.6Nm.
To prevent the possibility of a terminal short, use a pin terminal that has an
insulating sleeve.
The temperature rating of field installed conductors: 75°C only.
Confirm that all wires are connected correctly.
The torque required to tighten these screws is 0.5N•m to 0.6N•m.
To prevent the possibility of a terminal short, use a pin terminal that has an
insulating sleeve.
The temperature rating of field installed conductors: 75
o
C or less.
L
N
Open Button
FG
Black
White
Green/Yellow
(AC Power Cord included in the package)