Specifications
PL-6930 / PL-7930 Series User Manual
2-12
2.3 Interface Specifications
This section describes the specifications of each interface of the PL Series unit.
2.3.1 Serial Interfaces (COM1/COM2/COM3/COM4)
This interface is used to connect an RS-232C (serial) cable. A D-sub 9pin plug connector is used.
*
1
Number 9 pin's [RI/+5V]changeover is good only for COM2 and COM3. The factory default setting is
[RI]. For COM1 and COM4, [RI] can be available.
Use #4-40 (UNC)
fixing clamps to fix the joint of the interspace.
• The PL unit’s serial port is not isolated. When the host (PLC) unit is also not
isolated, be sure to connect the #5 SG (Signal Ground) terminal to reduce the risk
of damaging the RS-232C circuit.
• Inside the PL unit, the SG (Signal Ground) and FG (Frame Ground) terminals are
connected.
• If you connect an external device to the PL using the SG terminal, make sure that
no short-circuit loops are formed in the system design proceedings.
Pin
Arrangement
Pin No.
RS-232C
Signal Name Direction Meaning
1 CD Input Carrier Detect
2 RD(RXD) Input Receive Data
3 SD(TXD) Output Send Data
4 ER(DTR) Output Data Terminal Ready
5 SG(GND) - Signal Ground
6 DR(DSR) Input Data Set Ready
7 RS(RTS) Output Request to Send
8 CS(CTS) Input Send Available
9 CI(RI)/5V Input/Output
Called status display/+5V Output
(Switching available*
1
)
FG FG -
Frame Ground
(Common with SG)
• The ground (GND) is a signal ground. Make sure to connect it with the other unit’s
SG (Signal Ground) pin.
• The COM4 is not allowed to use when the communication procedure to the Touch
Panel is applied to a COM port connecting.
9
6
5
1