8.3 Periodic Inspection Items
Be sure to inspect the PL periodically to ensure it is in good working condition.
Ambient environment check points
Is the ambient temperature within the specified range?
• Is the ambient humidity within the specified range (10%RH to 85%RH)?
• Is the atmosphere free of corrosive gas?
Electrical specifications check
• Is the voltage adequate (AC85V to AC265V, 50Hz to 60 Hz)?
Installation check points
• Are all connection cables firmly connected?
• Are any bolts or screws loose?
• Are there any flaws or tears on the moisture resistant gasket?
Display check
• Is the display bright enough?
Ambient Operating
Temperature
PL693*-T41, PL793*-T41
Model without FAN
(CPU: CeleronM 1.3GHz)
5 °C to 40 °C (When using HDD)
0 °C to 40 °C (When NOT using HDD)
PL693*-T42, PL793*-T42
Model attached FAN
(CPU:PentiumM1.6GHz or
CeleronM 1.3GHz)
5 °C to 50 °C (When using HDD)
0 °C to 50 °C (When NOT using HDD)
• When the PL’s backlight needs to be replaced, please contact your nearest authorized service