Specifications
Type A1/A2
Rated Voltage
Max. Allowable Voltage
Input Type
Rated Current
Input Resistance
Standard
Operating Range
Input Delay
Common
Common Structure
External Connection
Input Points
Input Signal Indication
Isolation Method
External Power Supply
Rated Voltage
Rated Voltage Range
Output Type
Output Delay
Max. Load Current
Output Voltage Drop
Leakage Current when OFF
Output Classification
Common
Common Structure
External Connection
Output Protection Classification
Internal Fuse
Surge Suppression Circuit
Output Points
Output Signal Indication
Isolation Method
External Power Supply
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
COM (0V:DOUT)
COM (0V:DOUT)
NC
NC
DOUT15
DOUT14
DOUT13
DOUT12
DOUT11
DOUT10
DOUT9
DOUT8
DOUT7
DOUT6
DOUT5
DOUT4
DOUT3
DOUT2
DOUT1
DOUT0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
COM (24V:DIN)
DC24V (DOUT)
NC
NC
DIN15
DIN14
DIN13
DIN12
DIN11
DIN10
DIN9
DIN8
DIN7
DIN6
DIN5
DIN4
DIN3
DIN2
DIN1
DIN0
Front View*
B1
A20
A1
B20
Connection Method
Solder-type*
Model Name
GLC100-DIOCN01
Pin Signal Pin Signal
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
COM
(
24V
:
DOUT
)
COM
(
24V
:
DOUT
)
NC
NC
DOUT15
DOUT14
DOUT13
DOUT12
DOUT11
DOUT10
DOUT9
DOUT8
DOUT7
DOUT6
DOUT5
DOUT4
DOUT3
DOUT2
DOUT1
DOUT0
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
COM
(
0V
:
DIN
)
0V
(
DOUT
)
NC
NC
DIN15
DIN14
DIN13
DIN12
DIN11
DIN10
DIN9
DIN8
DIN7
DIN6
DIN5
DIN4
DIN3
DIN2
DIN1
DIN0
Front View*
B1
A20
A1
B20
Pin Signal Pin Signal
Type
Manufacturer
Solder type
Crimp type
Press-fit type
Connector
Fujitsu Takamizawa
Components
FCN-361J040-AU
FCN-360C040-B
(Connector)
(Cover)
FCN-363J040
FCN-363J-AU/S
FCN-360C040-B
(Connector)
(Contact)
(Cover)
FCN-367J040-AU/F
(Connector)
The sink/source type DIO integrates 16 input/output points into a compact unit.
The Type A1/A2/B+ LT supports up to 16-point inputs and 16-point outputs, ideal for connecting peripheral I/O devices.
5mA (24V)
4.7kΩ
ON voltage: 21V or more.,
OFF voltage: 7V or less.
OFF ON: 10ms or less.,
ON OFF: 10ms or less.
DC24V
DC26.4V
Source/Sink input
1
16 points / 1 common line
40-pin connector(also used for output)
16
LED lights for each point ON (logical side)
Photocoupler isolation
For Signal: DC24V
Type B+ Type A1/A2 Type B+
5.7mA (24V)
4.2kΩ
ON voltage: 15V or more.,
OFF voltage: 5V or less.
OFF ON: 1.5ms or less.,
ON OFF: 1.5ms or less.
DC24V
DC24V±10%
Type A1: Sink output
Type A2: Source output
Sink output
1.5V or less
OFF ON: 1ms or less.,
ON OFF: 1ms or less.
0.1mA or less
2.5V or less
OFF ON: 2ms or less.,
ON OFF: 2ms or less.
0.4mA or less
0.2A/point, 1.6A/common
Transistor output
1
16 points/ 1 common line
40-pin connector (also used for input)
No protection
3.5A,125V chip fuse (not replaceable)
Diode
16
LED lights for each point ON (logical side)
Photocoupler isolation
DC24V
* This front diagram shows the connector on the DIO unit side.
When preparing the cable, note that the
A and B characters indicate the number 1 pins.
* This front diagram shows the connector on the DIO unit side.
When preparing the cable, note that the
A and B characters indicate the number 1 pins.
*Set includes FCN-361J040-AU (connector) and FCN-360C040-B (cover)
This I/F unit's high-speed remote I/O (6Mbps/12Mbps) is so fast, you won't think you are using a remote connection.
Up to 1008 I/O points can be connected, with a communication delay of only 0.94ms (for 512 points at 12Mbps).
The network can be extended up to 400 meters (2 channels at 6Mbps).
* Dotted line shows the source output device connection.
* Dotted line shows the source output device connection. * Dotted line shows the sink output device connection.
Input Circuit Output Circuit
Input Circuit Output Circuit Input Circuit Output Circuit
Pin No.
6
5
4
3
2
1
6
5
4
3
2
1
Condition Signal Name
Channel 2 shield line
Channel 2 communication data
Channel 2 communication data
Channel 1 shield line
Channel 1 communication data
Channel 1 communication data
SLD
TR-
TR+
SLD
TR-
TR+
1: N
Multi-Drop Connection
6Mbps/12Mbps (selectable)
Differential Method, pulse transfer resistance
Format, bit, or CRC-12 verification
200m/channel at 6Mbps,
100m/channel at 12Mbps
During cyclic period, distributed transmission.
Half-duplex
63 (max.), 1008 I/O points
(depending on type of units used.)
Communication Configuration
Connection Method
Max. Distance
Communication Method
Communication Speed
Communication I/F
Error Check
Max. Number of Nodes
Serial I/F
Asynchronous: RS-232C/RS-422;
data length: 7 or 8 bits;
stop bit: 1 or 2 bits; parity: none,
Transmission rate: 2400bps to 115.2Kbps
1
2
3
4
5
6
7
8
9
10
11
12*
13*
14
15
16
17
18
19
20
21
22
23
24
25
FG
SD
RD
RS
CS
NC
SG
CD
TRMX
RDA
SDA
RESERVE
RESERVE
VCC
SDB
RDB
NC
CSB
ERB
ER
CSA
ERA
NC
NC
NC
Frame Ground
Send Data (RS-232C)
Receive Data (RS-232C)
Request Send (RS-232C)
Clear Send (RS-232C)
No Connection
Signal Ground
Carrier Detect (RS-232C)
Termination (RS-422)
Receive Data A (RS-422)
Send Data A (RS-422)
Reserved
Reserved
5V ±5% Dutput 0.25A
Send Data B (RS-422)
Receive Data B (RS-422)
No Connection
Clear Send B (RS-422)
Enable Receive B (RS-422)
Enable Receive (RS-232C)
Clear Send A (RS-422)
Enable Receive A (RS-422)
No Connection
No Connection
No Connection
Front View
1
13
14
25
Pin Code Signal Name
*Pins 12 and 13 are reserved and are not available for connection.
Recommended Connector:
Recommended Cover:
Recommended Cable:
Dsub 2
5
-pin plug XM2A-2501 (Omron)
Dsub 2
5
-pin cover XM2S-2511 (Omron)
Jack Screw XM2Z-0071 (Omron)
* Use M2.6 x 0.45 coarse thread screws to mount.
CO-MA-VV-SB5P 28AWG (Hitachi Cable,ltd)
4ms or less
4ms or less
1mA/DC5V
100mΩ or less
Set Time (at 20˚C)
Reset Time (at 20˚C)
Min. Switching Load
Initial Contact Resistance
Contact Rating
Tool Connector
Asynchronous: TTL level non-procedural command I/O
During Screen File Deveropment : Connect data transfer cable
for transferring data from GP-PRO/PB C-Package.
During Operation : Connect a variety of devices including a bar-code reader.
When the LT unit’s power is turned ON, the Alarm Output is
turned OFF for approximately 1 second. Be sure to design
your circuits to disregard a 1 second Alarm Output stop
after the LT unit’s power is turned ON.
Note: This relay switch is OFF from the time the power is turned on
until the LT Series system is booted. The external monitoring
circuit must be started after the LT Series system is booted.
ALARM
AC125V at 0.15A (resistive load),
DC24V at 0.6A (resistive load)
Refer to the GP-PRO/PB External Device Connection Manual (included with the
GP-PRO/PB C-Package) for external controller connection information, or visit our website.
+ -
COM
Internal Circuit
Internal Circuit
OUT
0V
B2
A5
A2
A1
OUT
IN
COM
IN
Internal
Circuit
Internal
Circuit
+ -
B5
B1
- +
*
IN
COM
IN
Internal Circuit
Internal Circuit
- +
B5
B1
+ -
*
- +
COM
Internal Circuit
Internal
Circuit
OUT
+24V
B2
A5
A2
A1
A20
B20
A20
B20
A20
OUT
DC 24V
External
Power Supply
DC 24V
External
Power Supply
DC 24V External
Power Supply
3.5A
3.5A
3.5A
Quick Break Fuse
Quick Break Fuse
A20
DC 24V External
Power Supply
DC 24V External
Power Supply
DC 24V External
Power Supply
IN
COM
IN
Internal
Circuit
Internal
Circuit
- +
B5
B1
+ -
*
B2
A5
- +
A1
+24V
OUT
COM
OUT
A2
Internal Circuit
Internal Circuit
Quick Break Fuse
09
LT Series Built-in Interface Specifications
LT Series Built-in Interface Specifications
10
See our Web site for LT Series system application examples.