Specifications

FN-X16TS41 FN-XY08TS41 FN-Y08RL41 FN-Y16SK41 FN-Y16SC41
DC24V
DC20.4V to DC28.8V
10ms or less (for DC24V power supply)
1.5W or less 1.0W or less 1.5W or less
AC1500V at 10mA for 1 minute (between power/Input and Output, and FG terminals)
Above 10M at DC500V (between power/Input and Output, and FG terminals)
0˚C to 55˚C
–25˚C to +70˚C
5% RH to 95% RH (non-condensing) wet bulb temperature: less than 39˚C
5% RH to 95% RH (non-condensing) wet bulb temperature: less than 39˚C
0.1mg/m
3
or less (non-conductive levels)
Free of corrosive gases
5Hz to 55Hz, 60m/s
2
in X, Y, Z directions for 2 hours each
Noise voltage: 1000Vp-p, Pulse Duration: 1µs, Arise time: 1ns
Contact discharge of 6kV (IEC 61000-4-2 Level 3)
Using 35mm DIN rail or screws
Natural air circulation
0.15kg [0.33lb] or less
W108mm [4.25in] x H45mm [1.77in] x D49mm [1.92in]
IP20 *
1
DC24V
DC28.8V
16 points
(common for sink/
source types)
8 points
(common for sink/
source types)
––
Type 1 *
2
––
––
––
DC15V or more
––
DC5V or less
––
4.1k
––
1.5ms or less
––
1.5ms or less
––
––
DC24V
DC20.4V to DC28.8V
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
––
Model
Unit Rated Voltage
Allowable Voltage Range
Allowable Voltage Drop
Internal Power Consumption
Voltage Endurance
Insulation Resistance
Electrical
Environmental
Structural
Input/Output
InputOutput
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Air Purity
Corrosive Gases
Pollution degree 2Pollution Degree
Vibration Resistance
Noise Immunity (via noise simulator)
Electrostatic Discharge Immunity
Installation Method
Cooling Method
Weight
External Dimensions
Rating
Rated Input Voltage
Max. Input Voltage
Input Points
Input Type
Input ON Voltage
Input OFF Voltage
Input Impedance
Input
Delay
Output
Delay
Rated Output Voltage (from V+ to V–)
Voltage Range (from V+ to V–)
Max. Load Voltage
Clamp Voltage
Leakage Current
OFF – ON
ON – OFF
OFF – ON
ON – OFF
5ms or less
1A at AC240V (resistive
load, dielectric load)
1A at DC24V (resistive
load, dielectric load)
0.1mA
1mA/DC5V
50m or less
100,000 operations or more
20,000,000 operations or more
1
Contact Rating
Min. Closing Load
Initial Contact Resistance
Electrical Lifetime
Mechanical Lifetime
Number of Occupied Nodes
No. of Output Points
8 points
(open drain
sink output)
16 points
(open drain
sink output)
16 points
(open drain
source output)
8 points
0.2A/point (8 points/
1 common, max.
common current 1.6A)
0.2A/point
(16 points/1 common,
max. common current 2.0A)
1.0A/point (8 points/
1 common, max.
common current 4.0A)
Short-circuit Protection
None None
––
––
––
––
––
––
10ms or less
DC1.5V or less
0.1mA or less
Voltage Drop (ON Voltage)
DC39V±1V
DC1.5V or less
DC39V±1V
1ms or less
1ms or less
1ms or less
1ms or less
––
16-point
Sink/Source Input
8-point
Relay Output/
1 Common
8-point
Sink/Source Input,
8-point Sink
Transistor Output
16-point
Sink Output
16-point
Source Output
*1 When terminal is tightened.
*2 Digital input for detecting signal from relay contact points, push buttons, switches or other mechanical contact point devices.
AND
EN DN
A
C
B
OR
EN DN
A
C
B
XOR
EN DN
A
C
B
NOT
EN DN
AC
P
N
M
R
S
M
I
RM
SM
MUL
EN DN
AC
B
SUB
EN DN
AC
B
ADD
EN DN
AC
B
SHR
EN DN
AC
N
ROL
EN DN
AC
N
FMOV
EN DN
AD
B
C
BMOV
EN DN
AE
B
C
D
MOV
EN DN
IN OUT
EQ
EN
A
Q
B
GT
EN Q
AC
B
GE
EN Q
A
B
DIV
EN DN
AC
B
DEC
EN DN
A
INC
EN DN
A
Normally Open
NO
LT
EN Q
A
B
LE
EN Q
A
B
NE
EN Q
A
B
TAN
EN DN
AB
SIN
EN DN
AB
COS
EN DN
AB
TON
IN Q
PT ET
ASIN
EN DN
AB
ACOS
EN DN
AB
ATAN
EN DN
AB
COT
EN DN
AB
EXP
EN DN
AB
LN
EN DN
AB
FOR
EN DN
A
NEXT
MOD
EN DN
AC
B
TOF
IN Q
PT ET
TP
IN Q
PT ET
CTU
CE Q
R
PV CV
CTD
CE Q
R
PV CV
CTUD
CE Q
UP QU
RQD
PV CV
ENCO
EN DN
AB
DECO
EN DN
AB
BCD
EN DN
AB
BIN
EN DN
AB
DEG
EN DN
AB
Normally Closed NC
Positive
Transition
Negative
Transition
PT
NT
Output Coil OUT
Retention Coil M
Negated Coil NEG
Negated
Retention Coil
NM
Unlatch Coil RST
Unlatch
Retention Coil
RM
Latch Coil SET
Logical
Multiply
Arithmetic Operation Instructions
AND
Latch
Retention Coil
SM
Bit Negation NOT
Logical Add OR
Exclusive
Logical Add
XOR
Block Transfer
Movement Instructions
Shift
Instructions
BMOV
Fill Transfer FMOV
Transfer MOV
Rotate Left ROL
SHL
EN DN
AC
N
ROR
EN DN
AC
N
Rotate Right ROR
Shift Left SHL
Shift Right SHR
SUM
EN DN
AD
B
C
Sum SUM
Add
Mathematical Instructions
Comparison
Instructions
Comparison Instructions
Special
Instructions
ADD
Subtract SUB
Multiply MUL
Divide DIV
Residual
Processing
MOD
Decrement DEC
Increment INC
Equal To (=) EQ
Greater Than (>) GT
Greater Than
or Equal To (>=)
GE
Less Than (<) LT
Less Than
or Equal To (<=)
LE
Not Equal (<>) NE
On Delay Timer
Timer and Counter InstructionsConvert Instructions
TON
PID
EN DN
SP
PV
TB
CV
PID
Calculation
PID
Off
Delay Timer
TOF
Timer Pulse TP
Up Counter
CTU
Down Counter
CTD
Up/Down
Counter
CTUD
BCD
Conversion
BCD
Encode ENCO
Decode DECO
Binary
Conversion
BIN
Degree
Conversion
DEG
RAD
EN DN
AB
Radian
Conversion
RAD
sine function
SIN
cosine function COS
tangent function
Function Control Instructions Convert InstructionsProgram Control Instructions
TAN
Arc sine ASIN
Arc cosine ACOS
Arc tangent ATAN
Cotangent COT
Exponent EXP
Natural
logarithm
LN
SQRT
EN DN
AB
Square Root SQRT
Jump JMP
BCNT
EN DN
AB
Average AVE
Bit Count BCNT
AVE
EN DN
AD
B
C
SAL
EN DN
AC
N
SAR
EN DN
AC
N
Left Rotation
with Carry
RCL
Right Rotation
with Carry
RCR
Arithmetic
Shift Left
SAL
Arithmetic
Shift Right
SAR
RCL
EN DN
AD
N
C
RCR
EN DN
AD
N
C
Jump to
Subroutine
JSR
Return from
Subroutine
RET
Repeat
FOR
NEXT
Type
Class
Inst. Symbol Type
Class
Inst. Symbol Type
Class
Inst. Symbol Type
Class
Inst. Symbol
Discrete instructions
Shift Instructions
17
LT Series Ladder Logic Instruction List and Remote I/O (Flex Network)
LT Series Ladder Logic Instruction List and Remote I/O (Flex Network)
18
See our Web site for LT Series system application examples.