Hardware manual

LT-4201TM/4301TM (Modular Type DIO)
96
Digital Outputs
Overview
The rear module is equipped with 10 transistor outputs that you can manage
(see page 47).
Output Management Functions Availab
ility
The table describes the possible usage of th
e rear module outputs:
Fast Output Wiring Diagram
For additional information about fast output protection, refer to
Protecting Outputs
from Inductive Load Damage (see page 35).
DANGER
FIRE HAZARD
Use only the recommended wire sizes for I/O channels an
d power supplies.
Failure to follow these instructions will result in death or serious injury.
Function
Output Function
Standard Output Pulse Output/
PWM Output
Fast
Output
1
Q0 X
Q1 X
Digital
Output
Q2 X
Q3 X
Q4 X
Q5 X
Q6 X
Q7 X
Q8 X
Q9 X
Q10 X
Q11 X
X Yes
No
1
Can not be used as a Standard output
WARNING
UNINTENDED EQUIPMENT OPERATION
Be sure to wire the outputs correctly according to the wi
ring diagram.
Failure to follow these instructions can result in death, serious injury, or
equipme
nt damage.