User`s manual

When the FG terminal is connected, be sure the wire is grounded.
Not grounding the GP unit will result in excess noise and vibrations.
Wherever you can, use thick wires (max. 2 mm
2
) for power termi-
nals, and provide an extra twist to the wire during connection.
Please use Ring Terminals with the size described below.
To avoid a short among the ring terminals when the screws get
*1 AC100V L=AC Input Terminal ..................... live line
AC100V N=AC Input Terminal ..................... neutral line
FG=Ground Terminal connected to the GP chassis
*
1
Ring Terminal to use: V2-MS3 (made by JST)
loosen, please use ring terminals with a sleeve.
Rear side
N
L
FG
L N FG
Ring Terminals*
1
7 Wiring
WARNING
To avoid electric shock, be sure the Power Cable is unplugged from the
power outlet when connecting the cable to the GP unit.
GP577R-TC11 and GP577R-SC11 can only take AC100V input. If you
supply power other than AC100V, you will damage its power supply and
the GP unit.
There is no power switch on the GP unit, so please use a breaker switch.
Power Input
Terminal Block
Under
6.0mm
Over φ 3.2mm