User`s manual
Chapter 7 - Maintenance
GP-477R/577R Series User's Manual
7-5
1) Turn the GP’s power OFF (i.e. disconnect the GP's power cord).
2) Use a Phillips screwdriver to remove the case’s two rear attachment
screws, and pivot the rear cover open, starting from the top of the
unit. (The cover is fastened at the bottom, and hinges open).
The rear cover cannot be completely removed. If you attempt to remove it,
you may break the cover.
3) Disconnect the upper backlight's power connector from the GP's
inverter.
4) Loosen the backlight unit holder's two attachment screws, and
remove the backlight unit's metal cover.
Since the attachment screws are small, be sure not to lose them or allow
them to fall inside the GP's case.
This unit has two backlights, one at the top and one at the bottom. The follow-
ing explanation is for changing the top backlight. To change the bottom
backlight, simply repeat the procedures shown here in the same order.
Be sure to change both backlights at the same time.
The GP577RT backlight's CFL tube and housing are combined in one
unit. Be sure to change only this combined unit.
Note:
nn
nn
n How to replace the GP577RT's backlight
STOP
STOP
!!
!!
!
Important
Top
Bottom