User`s manual

Chapter 6 - GP RUN and Errors
GP-477R/577R Series User's Manual
6-8
*1 Enter the password as setup in the INITIALIZE option, or the default password 1101.
This section explains the contents of SELF-DIAGNOSIS. For information
on how to operate the Screen, Chapter 4, "OFFLINE
Mode"; for information about how to set up the Special Tools,
Chapter 3, "Installation and Wiring".
CHARACTER PATTERN
Use this check, which runs the character ROM CHECK-SUM CHECK, when
characters do not display on the screen. Check each font pattern or the
Kanji ROM using the sub-menu displayed above. If everything is normal,
OK displays; if there is a problem, NG displays.
DISPLAY PATTERN
Used when the buzzer will not sound and when the device contents will not
display correctly to check the drawing function. It does this by running checks on
the various screen pattern displays (9 screens) and on the ON/OFF Display. When the
ON/OFF Display is checked, the Buzzer ON/OFF check is run simultaneously. If
everything is normal, OK displays; if there is a problem, NG displays.
TOUCH PANEL
Touch Panel check. Checks if each touch cell highlights when pressed.
INTERNAL FEPROM (SCREEN AREA)
When this check is carried out, all the contents in the memory
are erased. Please make sure that all data is backed up be-
fore running this check.
After running the check, initialize the internal memory (FEPROM)
This feature checks for any problems that may arise in the display. But to
run the check, a password
*1
is necessary.
When running the check, the screen will change as follows.
!!
!!
!
Important
Reference
Reference
2. SELF-DIAGNOSIS - Details