Specifications

The Video-mix Unit enables more
realistic monitoring and control
EASY SCREEN CREATION & LOGIC PROGRAM DEVELOPMENT
Screen Editor and Logic Program Development Software
GPPRO-CNT01W-P03
The GP-PRO/PBIII C-Package combines screen creation and
logic programming capabilities into one handy package.
Using the simple "settings navigator," even beginners can
create easy-to-use operating environments.
This function makes it easier to set up devices
and handle routine tasks.
Current values and set values can be changed
from the display screen.
Bit On/Off and word setting can
be scheduled by day of the
week or for a specific time.
The weekly and time setting
can also be changed on the
display device.
Restrict user access depending by operator level.
Use the 15-level password protection function to
restrict access to specific screens, such as
management and maintenance screens.
This protection function helps
to improve screen security,
which also means greater
safety for machines that are
unattended or installed off-site.
We expanded the setting parameter display
function for more efficient on-screen input.
Improved Keypad Display Function
Touch input for input mode activation.
A sequence designation function
for inputting multiple items
(with the group function).
Designation of the change
notification bit for individual setting
parameter displays.
A more flexible arrangement
for the popup keyboard.
Time Scheduling
The text screen now supports multiple
languages. A and X tags can be used
to display different languages.
Text Screen's Multi-language Function
Improved Editing
Expanded Alarm Summary
Display Function Using Q Tags
Security Level Function
Additionally, because the current values/set values
can be altered not only from the ladder monitor but
also the display screen, the
contact point's ON/OFF and
timer/counter's tuning can
be performed even if a
computer is not available.
Supports Ladder Monitor
15 kinds of ladder instructions, such as arithmetic
functions, have been added. This makes developing
programs much easier.
*Supported by GLC2000 series only
(except for GLC2400/2600's old revisions.)
Add New Instructions
Inserted commands and variables are graphically displayed,
making ladder programming mistakes easy to avoid.
More Convenient to Operate
INFORMATION
COMMUNICATION
CONTROL
System Design
Software
Data Collection SoftwareWeb Operation Software
SIO 1ch (COM1)
Ethernet
SIO
Expansion
Unit I/F
Flex Network
SIO 2ch (COM2)
Expansion Unit Interface
Remote I/O (Flex Network) System
32-point Sink/Source Input,
32-point Sink-type Transistor Output
FN-XY32SKS41
(Spring Clamp Connector)
FN-X32TS41 FN-XY16SK41 FN-XY16SC41
16-point
Sink/Source Input,
16-point Sink
Transistor Output
16-point
Sink/Source Input,
16-point Source
Transistor Output
32-point
Sink/Source Input
FN-Y16SK41 FN-Y16SC41
16-point
Source Output
16-point
Sink Output
FN-X16TS41 FN-XY08TS41 FN-Y08RL41
8-point Sink/Source Input,
8-point Sink Transistor Output
8-point Relay
Output/1 Common
16-point
Sink/Source Input
*1 4-channel Analog
Input / Output Units
are not CE marked,
UL/c-UL (CSA) listed
products.
FN-DA04AH11*
1
FN-HC10SK41 FN-PC10SK41
High-speed
Counter Unit
Single-axis
Positioning Unit
Teaching Loader
FN-PC10LD41
4-channel Analog
Output Unit
FN-AD04AH11*
1
4-channel Analog
Input Unit
Arc Sine
Arc Cosine
Natural Logarithm Loge(x)->y
Arc Tangent
Command Extensions Type
Information flows smoothly to and from the host PC
via CF card or Ethernet, forming a highly reliable
system for process control or data collection and
providing reliable, assured support for management
strategy building.
Data Collection and Distribution
Versatile interfaces support flexible expansion
for a control system that meets your needs.
Useful Interfaces to Meet Your Needs
GW-CJ01-V
**
PSW-ED01-V
**
Single-board
Computer
PC
PLC
Inverter Temperature
Controller
PROFIBUS DeviceNetCANopen
To connect various controllers
Serial devices, such as bar code
readers or two-dimensional code readers.
Fieldbus slave connection*
VM
Amplifier
Servomotor
1-axis
Positioning
Unit
Flex
Network
Precision equipment field,
semiconductor inspection line
GLC
Video images provide virtually on-site
monitoring of line conditions.
System
example...
Adding the Video-mix Unit enables high-precision
line surveillance and control over a single screen.
Remote operation and monitoring ensures trouble
free line control. Plus, the expandability of the
GLC2600T/2500T with the 3-way control opens up
a wealth of new production possibilities.
*Only for GLC2600T/2500T.
The remote I/O system contributes to more reliable,
high-speed control, cutting wiring costs and labor.
Distributed I/O Terminals
for up to 1008 Points
Secured and real-time data exchange with
commonly used PC applications over CF card,
Ethernet or the Internet.
*For details of Flex Network, contact
your local sales representative.
* Only available from Pro-Face Europe B.V.. For further information,
please contact Pro-face Europe B.V..
11 System Design Software 12
Surveillance
camera
Easy data
transfer by
CF card.
64-point I/O Unit 16-point I/O Units 8-point I/O Unit
High-spec Units
32-point I/O Units
EASY SCREEN CREATION LOGIC PROGRAM