Solution Sequence:
1. Disconnect AC power from the charging system. This indication may signify a possible battery problem.
2. Call technical support for further assistance (615.471.5300).
PROBLEM: A green LED was illuminated before disconnecting the power from the charger, but upon reconnection,
red LEDs appear and remain on.
This is the normal operating procedure for the system. It indicates that a reanalysis of the battery status was initiated and
after a series of steps the green LED will illuminate.
LIGHT EMITTING DIODES (LED) FAULT CODE INDICATIONS
The microprocessor is constantly monitoring the charger circuitry and will both detect and display blinking LED indications i
f a
fault is detected. The battery type LED will be
OFF
during a fault code condition.
When first connected to DC (AC not connected), the LEDs will display one or more of the following:
1. The LEDs will flash the charger’s ID code (this is for PCS internal use only). Once the LEDs flash the ID, they will only display one
yellow LED. This configuration will remain until AC is detected and a charge cycle is in progress.
2. There is also a possibility the LEDs will not flash their ID code and only show a yellow LED.
3. Lastly, the LEDs may not flash their ID code and may not show any LEDs until AC is detected.
If the AC line and neutral wires are reversed, the unit will wait 2 minutes before starting a charge. NOTE: The 2 minute wait period will also be a
factor if the charger is being powered by anything other than normal grid AC such as a conventional generator, inverter, etc.
If AC is disconnected while charging, the unit will turn off as expected. The user may hear some clicking noise, but should not be alarmed. This is
the Powered by Battery/DOE functionality checking for AC connection.
30 & 60% RED LEDS BLINKING ………………..…..…FORMING STAGE TIMEOUT SHUTDOWN
This indication occurs if the battery voltage has not risen above 1.75 volts per cell within the first 3 hours of charging. This indicates that a possible battery
problem exists and that the charge cycle has been terminated at this point.
30, 60 & 90% RED LEDS BLINKING............................................OVERALL TIMER SHUTDOWN
This indication occurs if the charger has not completed the charge cycle within the allowable factory set time period. This indicates that a possible battery
problem exists and that the charge cycle has been terminated at this point.
30 & 90% RED LEDS BLINKING..…..............................INTERNAL OVERTEMP SHUTDOWN
This indication occurs if the charger circuitry has detected operating temperatures inside the charger enclosure that are above factory specified levels. This
could indicate that a possible charger problem exists and that the charge cycle has been terminated.
30% RED & 100% GREEN LEDS BLINKING …..….......................... BULK STAGE SHUTDOWN
This indication occurs if the battery voltage does not rise properly during the Bulk Stage. This indicates that a possible battery problem exists and that the
charge cycle has been terminated at this point. Please call technical support for further assistance (
615.471.5300).
30% RED & 100% GREEN LEDS ALTERNATE BLINKING ON OFF…..…..................DELTAVIEW SIGNAL OR NO BATTERY DETECTED
This will be the NORMAL indication when the charger is plugged into A/C but not connected to a battery pack, allowing the DeltaView signal to be retrieved with
a DeltaView Reader. This can also be considered the NO BATTERY DETECTED fault code. Please call technical support for further assistance
(
615.471.5300).
Note: Disconnecting and reconnecting the AC power supply cord will reset the charger.
LIMITED WARRANTY
Pro Charging Systems, LLC (PCS) makes this Limited Warranty only to the original retail purchaser.
PCS warrants this battery charger for three years (unless the charger is used in a Restricted Market) from the date of retail
purchase against defective materials and/or workmanship. Restricted markets include markets outside of the USA, Rental
applications and Heavy Industrial applications. Sometimes RM is designated in the PCS Part number when ordered, but is
not part of the model number. Chargers used in Restricted Markets will have a warranty period of 18 months from the date of
retail purchase against defective materials and/or workmanship. CR refers to “Certified Reconditioned” and designates a 1
year warranty.