If water does not stream out of the water outlets while the
boat is moving forward, immediately stop the boat and clean
the obstruction from the water cooling system.
1. Disassemble and clean the water cooling system to
remove blockage and prevent overheating.
2. Replace any damaged parts.
NOTICE: The boat must run at least 30mph in order to
force water through the cooling system. Running the
boat below 30mph will prevent water from circulating
through the electronics, causing them to overheat and
possibly become damaged.
Throttle Range Calibration
Water Cooling System
12
1. Power on the transmitter and set the throttle TRIM dial to
the center position.
2. Install the batteries in the boat and connect the batteries
to the ESCs.
3. With the ESCs powered off, pull the throttle trigger to full
throttle and power ON both ESCs
simultaneously. The ESCs will beep twice. The green light
will fl ash with each beep.
4. Return the throttle to neutral. The ESCs will beep once
and the green light will fl ash once.
The calibration process is now complete. The ESCs will arm
with beeps and fl ashes to announce the number of battery
cells it has detected. Reverse calibration is unnecessary.