Installation Guide

Before installing the electric fireplace, please read the following steps carefully.
INSTALLATION
Find a safe location and build a suitable hole for fireplace. Minimum clearance from the ceiling and the mantel
must be at least 8 inches(200mm); minimum clearance from the front must be at least 3 feet(900mm). Choose a
location near an outlet so an extension cord is not required.
Take EF50R as a sample. Prepare a wall with a framed opening of 45.7 inch(1160 mm) wide X 17.05’’(433 mm) high.
Make sure the width of the wood block on both sides which used to fix the fireplace is 3’’(76mm). Make sure that the
revealed wood block width on both sides is about 1 1/2’’(37.5mm) after finishing the plasterboard. Measure the
depth D from the plasterboard surface to the wood block and write it down.
M O DEL
EF30R
EF36R
EF42R
EF50R
EF60R
EF72R
EF95R
A
25.7 ’’
(
652
mm)
31.7’’
(805 mm)
37.7’’
(
957
mm)
45.7 ’’
(11
60
mm)
55.7’’
(1414 mm)
67.7’’
(1720mm)
90.7’’
(2303 mm)
17.05’
ALWAYS unplug this fireplace heater before assembly or cleaning, or before relocating.
Failure to do so could result in electric shock, fire, or personal injury.
Warning
This carton includes GLASS! ALWAYS use extremely caution when handing
glass.
Failure to do so could result in personal injury or property damage.
Warning
INSTALLATION