User`s manual

368
Appendix F
Zebra
Xilll
Series T5000e with PPI1 Emulation
Label Top - (-120 to +120 dot rows) +00*.
Adjusts vertical print position on label.
QUICK SETUP Menu,
Ver Image Shift - (-1 to+12.8”) 0.0*”. Adjusts vertical print
position on label.
Or
IGP/PPI1 SETUP Menu,
Top Position - (-100 to +100 dots/inch)
0 dots/inch*. Adj vert. position in dot/in.
NOTE: Only avail. in later version SW.
Left Position - (-9999 to +9999)
0000*. Adjusts image horizontally from left
edge of label in dots.
(+) shifts image left. (-) shifts to right.
QUICK SETUP Menu,
Hor Image Shift - (-1.0 to +1.0) 0.0”*.
Adjusts image horizontally from left edge of label in
inches.
(+) shifts image left. (-) shifts image right.
Or
IGP/PPI1 SETUP Menu,
Left Position - (-1000 to +1000 dots) 0 dots*. Adjusts
image horiz. in dots.
NOTE: Only avail. in later version SW.
Head Test Count- (0000*-9999) 0000
disables test.
DIAGNOSTIC Menu,
Ptr Media Dist - Inches*, MM.
Head Resistor - Must be updated when
printhead changed.
NOTE: Head Resistance detected & updated
automatically by SW.
Verifier Port - How printer reacts to Optional
On-Line Verifier.
Off* - Verifier port is off.
1 VER-RPRINT - Label reprinted if error
detected.
2 VER-THRUPUT - Allows greatest
throughput but may not indicate verification
error immediately.
Off - Default if no validator installed.
VALIDATOR Menu (Opt),
Validator Funct. - Enable*, Disable. Automatically
Enabled when opt installed. Disable = Validator turned off.
Validator Action -
Retry Form* - Label reprinted if error detected.
Applicator Port N/A
Web S. - Auto set during calibrate. Automatically set during Auto Calibrate.
Media S. Auto set during calibrate. Automatically set during Auto Calibrate.
Ribbon S. - Auto set during calibrate. Automatically set after power up, while printing and when
printhead is opened then closed.
Mark S. - Auto set during calibrate. Automatically set during Auto Calibrate.
Mark Med S. - Auto set during calibrate. Automatically set during Auto Calibrate.
Media LED - Automatically set during
calibrate.
Automatically set during Auto Calibrate.
Table 32: PPI1 Menu (continued)