Chapter 3 Emulation Submenus
Lead-in Chars
(From page 159, page 161, page 171, page 173.) You can enable additional
printer features which are not accessible through standard coax emulations.
To access these features, send text commands in the data stream. The
commands must have a start and end code. Three sets (each containing a
start and end code) are available:
Set 1 start code: <%
end code: >
Set 2 start code:¬¬
end code: $
Set 3 start code: _%
end code: _
The factory default is Set 1<%>.
Left Margin
(From page 184, page 187, page 189, page 191, page 193.)
Set in characters. Character zero is defined as the far left edge of the page,
and column numbering increments from left to right.
The range is 0-369 characters, and the factory default is 0 characters.
Left Position
(From page 181.) The ^LS command specifies a horizontal offset to be added
to all label element positions. The Left Position option displays the value
specified by the ^LS command and provides an alternative method for
specifying the horizontal offset.
The factory default is 0.
Logical Buf Size
(From page 164.) Refers to the size of the printer buffer, which should be set
the same as the host screen (buffer) size. If the host screen size is unknown,
use 1920.
The options are 960, 1920, 2560, 3440, and 3564.
The factory default is 1920.
LP+ Text Mode
(From page 181.) PPI supports text printing using the LP+ emulation.
Absorb. Use this setting for ZPL compatibility. This setting absorbs
non-PPI data.
Auto Pass-thru. Use this setting for text printing. Non-PPI data is passed
to the LP+ emulation.