Specifications
General Commands
265
Table 22. General PTX_SETUP Commands
Command Sub-Command Parameter Description
CONFIG LOAD Cfg Cfg can be 0-8. The PTX_SETUP
will load configuration Cfg. If
configuration Cfg was not previously
saved, the operator panel will
display an error message and the
current configuration will be kept.
SAVE Cfg Cfg must be 1-8. This command will
save the current configuration as
configuration Cfg. If Cfg is not in the
range of 1-8, the command is
ignored.
SETMENU Value;Menu_tag Menu_tag is the name of the menu
as defined in the menu file. Value is
the value to which the menu is to be
set.
POWERUP Cfg Sets the power-up configuration to
Cfg and loads Configuration Cfg.
Cfg can be any value from 0-8,
where 0 is the factory default.
PRINT Cfg Print Configuration Cfg. Cfg can be
a number 1-8, or one of four pre-
defined configurations. The four
non-numeric configurations are
requested using the first character
for the CURRENT, FACTORY,
POWERUP, or ALL configuration(s).
DELETE Cfg Deletes Configuration number Cfg.
Cfg must be in the range of 1-8.
UPLOAD Port;Cfg This command uploads the
configuration stored in location Cfg
to the port specified by Port. Port
must either be 1284 or SERIAL. Cfg
may be 1-8 or ALL.
DOWNLOAD Cfg This command saves the
configuration data that follows as
configuration Cfg. Cfg must be 1-8
or END.