Owner's manual
294
Chapter 7
Data Validation
•
Overall Grade Failure:
This is an overall data validation failure. One or
more of the following errors has occurred: Decodeability, Percent
Decode, Defects, Modulation, Minimum Edge Contrast (EC Min),
Minimum Reflectance (Rmin), and/or (Symbol) Contrast.
The printer’s next action depends on the error action setting. If the Stop
mode is selected, printing resumes where the printing stopped. If the
Overstrike or Reprint modes are selected, the printer assumes the last
label failed and takes the appropriate action. See “Error Action” in the
Online Data Validator User’s Manual.
RFID
This is the message assigned for an RFID failure.
Pass = no RFID failure
Tag Failure = RFID failure
8. Job ID
The default is 65535. For future use.
9. Pages Completed
The default is 0. For future use.
Bar Code Data Fields
These are the available bar code data fields:
Decoded Data Horizontal Position
Deviation Vertical Position
Symbology Good Scans on Code
Letter Grade Total Scans on Code
Ref Decode Good Quiet Zones
Decodeability Avg Lead QZ In X’s
Modulation Avg Trail QZ In X’s
Defects Avg Sync State
Edge Contrast Avg X Units Times 10
Rmin/Rmax Avg Percent Good Global Thresholds
Symbol Contrast Avg PDF 417 Gap Failure
PCS Avg Decodeability Failure
R(White) Avg Defects Failure
R(Black) Avg Percent Decode Failure
Ratio Avg Quiet Zone Failure
Bar Deviation Avg Symbol Contrast Failure
Minimum Bar Dev Avg Encodation Failure