Owner's manual

Viewing Telemetry Data
293
Other Error Messages
Calibration Warning:
In some cases, the validator can determine if it is
out of calibration. When this occurs, the validator will communicate this
condition as part of a bar code report. This condition is considered a
warning and the printer will not stop.
NOTE:
If a bar code failure is also reported in the same bar code report, then
failure error handling will take precedence.
When the calibration warning condition is encountered, the message
“Validator needs calibration” displays. Normal operation will continue
during this warning. To clear the message, press the
PAUSE
key.
Once the message has been cleared, perform the calibration procedure
(see “Calibration” in the Online Data Validator User’s Manual). Whether or
not you perform a calibration will be unknown to the printer. Once the
warning message has been cleared, the printer will assume that any
problem has been resolved and will function as normal.
7 Decodeability Unscannable code
Check media
8 PDF 417 Gap Poor scanning
Check media
9 Calibration Calibration
Warning
10 Overall Grade Failure Overall Grade
Failure
11 Internal Data Format
Error
Error
Data invalid
12 Modulation Modulation Fail
Check head&heat
13 Minimum Reflectance RMin Fail
Check head&heat
14
(lowest)
Minimum Edge
Contrast
Edge Ctst Fail
Check head&heat
Priority Failure Message
Operator Panel
Message