Manual
164
Chapter 7
Diagnosing Problems
GRF CHK ERROR
PRESS STOP
Yes Graphic Check Error: in the
CT emulation over a twinax
interface, the printer
received a non-printable
character.
Press CLEAR and then ON
LINE.
H00: PCI SLOT ?
See User Manual
No The controller board is not
communicating with a PCI
card. This could indicate a
bad PCI card, poor
connection, or problem in
the PCI bus.
Contact your authorized service
representative.
1
H01: PCI J12
See User Manual
No The controller board is not
communicating with the PCI
card in PCI slot J12. This
could indicate a bad PCI
card, poor connection, or
problem in the PCI bus.
Contact your authorized service
representative.
1
H02: PCI J13
See User Manual
No The controller board is not
communicating with the PCI
card in PCI slot J13. This
could indicate a bad PCI
card, poor connection, or
problem in the PCI bus.
Contact your authorized service
representative.
1
<Online, etc...>
Half Speed Mode
No Status message: The
controller samples the
operating temperature of key
components of the print
mechanism. When higher
than normal temperatures
are sensed, the print speed
is automatically reduced by
50% and the message sent
the LCD. When the
components cool down, the
print speed returns to 100%
and the message clears.
No action is required. If the
message appears often, contact
your authorized service
representative.
1
HAM. COIL OPEN* No Hammer Coil Open.
Electrical malfunction of one
or more hammer coils.
Contact your authorized service
representative.
1
HAMMER SHORT*
See User Manual
No Electrical malfunction of one
or more hammer coils.
Contact your authorized service
representative.
1
INTAKE FAN FAULT Yes Sensors cannot detect
current in fan circuit.
Cycle power. If the message
appears, press CLEAR. If the
message does not clear, contact
your authorized service
representative.
1
Table 10. LCD Message Troubleshooting Table
Displayed Message
Can User
Correct?
Explanation Solution