Manual

Chapter 2
Configuring the Validator
76
The following is a sample scan report of a Code 39, 10 mil bar code
containing "*PTX8702*" with a quiet zone violation:
SCAN REPORT
ERROR: Bar code quiet zone too small
Barcode Data: [ST]PTX8702[ST]
Symbology Code 39
Overall Grade C (2.1)
X dimension (mils) 09.9
Decodeability (%) 65
Modulation (%) 34
Symbol Contrast (%) 68
Edge Contrast (%) 30
Defects (%) 14
Rmin/Rmax 2
PCS 92
Percent Decode (%) 100
Bar Deviation Avg (%) -16
Min. Bar Deviation (%) -31
Max. Bar Deviation (%) -4
Ratio 2.0
Good Scans 28
Total Scans 30
Scan Profile
This is an executable menu that prints the scan reflectance profile
of a bar code placed in the validator scanning beam.
NOTE:
You will need a minimum installed label width of 2 inches
to support the Scan Profile printout.
1. Press to take the printer offline and place the printer in
Menu mode.
2. If necessary, press
and
at the same time to unlock the
key.
3. Press until VALIDATOR displays.
4. Press
until Scan Profile displays.
5. Place a bar code in the scanning beam path.
6. Press
to scan the bar code.
7. When prompted on the control panel, remove the scanned bar
code.
8. Press
to print the scan profile.
.
.
.
.
.
.