SN Threshold
This menu item sets the SN (signal to noise) threshold used by the
validator to discriminate between high peak noise and actual bar
code transitions. Any reflectance transitions that are below the
threshold are ignored and considered noise.
You can set the SN Threshold to a value from 5 to 199.
The default is 70.
1. Press to take the printer offline and place the printer in
Menu mode.
2. If necessary, press
and
at the same time to unlock the
key.
3. Press until VALIDATOR displays.
4. Press
until SN Threshold displays.
5. Press
+
or
to scroll through the values: 5 to 199.
The default is 70.
6. Press
to select the desired value.
7. Press
and
at the same time to lock the
key, then press
PAUSE
to take the printer offline.
8. Press
PAUSE
again to put the printer online.
.
.
.
.
.
.