Manual

Advanced Validator Options
65
7. Press
and
at the same time to lock the
key, then press
PAUSE
to take the printer offline.
8. Press
PAUSE
again to put the printer online.
Percent Decode
NOTE:
This parameter factors into the Overall Grade (page 66).
You can set how strict the validator grades each bar code. For
example, setting Percent Decode to 60% means that 60% of the
scanned bar code must be readable for the validator to give the bar
code a passing grade. You can set the Percent Decode parameter
to a percentage value from 0% to 99%. The higher the percentage
value chosen, the stricter the validator grades.
1. Press to take the printer offline and place the printer in
Menu mode.
2. If necessary, press
and
at the same time to unlock the
key.
3. Press until VALIDATOR displays.
4. Press
until Percent Decode displays.
5. Press
+
or
to scroll through the percentage values: 0% to
90%. The default is 0%.
6. Press
to select the desired value.
7. Press
and
at the same time to lock the
key, then press
PAUSE
to take the printer offline.
8. Press
PAUSE
again to put the printer online.
Defects
NOTE:
This parameter factors into the Overall Grade (page 66).
You can set how strict the validator grades the irregularities such as
voids and spots found within elements and quiet zones for each bar
code. For example, the Defects default is 21%. This means that if
the bar code and quiet zone defects exceed 21%, the validator
gives the bar code a failing grade. You can set the Defects
parameter to a percentage value from 0% to 100%. The lower the
percentage value chosen, the stricter the validator grades.
.
.
.
.
.
.