Manual
203
Level H Maintenance - 2,400,000 Pages (User)
Action Item Part #
Performed
By
Date
Clean Flash power supply filter n/a
Replace Main charger 705741-001
Replace Precharger 705742-001
Replace Transfer charger 705743-001
Replace
(See Note 1)
Cleaning unit 705740-001
Replace Smoke filter 703540-001
Replace Transporting belt-3 703531-035
Replace Lamp housing filter 202985-001
Replace Capacitor: See
WARNING
on following page.
The flash fuser capacitors
(P/N 703542-001) must be
replaced at least every
2,400,000 pages. Failure to
do so may endanger
equipment and personnel.
703531-001
Replace LED for discharge lamp 703531-118
Replace EPS1, EPS3, and EPS4
Sensor Levers
703531-585
703531-588
703531-067
Replace Trigger coil unit for GP150L 703531-165
Replace Exit feed roller drive belt 203090-001
Note 1: When the cleaning unit has been vacuumed every 150,000 pages and has
been used under normal operating conditions, it must be replaced at 600,000 pages.
However, it may need to be replaced more frequently if used for high-density printing
or printing on uneven media, or if used under severe operating conditions.