User's Manual
IPG/PGL Setup Submenus
151
Ignore Text
• Disable. When disabled, text in normal mode will be printed. Attributes to
be printed depend on the PGL Normal menu setting.
• Enable. When enabled, any line of text (non-PGL commands) in normal
mode will be ignored.
The factory default is Disable.
Power on IGP/PGL
You can set the IGP/PGL feature so that it is enabled or disabled when the
printer is powered on.
• Enable (the default). The IGP/PGL is enabled when the printer is
powered on. (The IGP/PGL feature is initialized in the Normal mode.)
• Disable. The IGP/PGL is disabled when the printer is powered on. (The
IGP/PGL feature is initialized to the Quiet mode.)
Ext Execute Copy
• Disable. Dynamic data, overlay data, etc. are not allowed if the optional
Form Count parameter (number of forms to print) is specified as part of
the Execute command. (This setting is IGP-100 compatible.)
• Enable. Dynamic data, overlay data, etc. are allowed within a form where
the Form Count parameter is specified in the Execute command. In this
case, the same form is printed for whatever the Form Count is.
Incremental data is not incremented since the printing page is the same.
The overlay data is only printed with the first form and not on subsequent
forms, and each form is printed on a separate page.
The factory default is Disable.
AI 00 Spaces
This option is designated for EAN/UCC-128 barcodes whose application
identifier (AI) is 00.
• Disable. The printable data field is printed with the AI enclosed in
parentheses. This is the standard EAN/UCC-128 format.
• Enable. The printable data field is printed with the UCC fields separated
by spaces. This option is IGP-X00 compatible.
The factory default is Disable.
Select SO Char
Allows you to specify a decimal code from 0 through 255 to be used in place
of SO (Shift Out) as the control code which allows access for the alternate set
of control function characters. See the description of the Code 128 barcodes
in the
PGL Programmer's Reference Manual
for details.
The range is 0-255, and the factory default is 14.