Operator`s manual

USING REMOTE SETUP
92
with 1 at the [BeginPrintekSetup] heading line. Any lines
preceding this will not be processed, and will not be counted.
Before sending the remote setup file to the printer, minimal setup is
required via the front panel setup menus. The I/O interface to be used for
remote setup must be configured appropriately to communicate with the
host system, and the "
Test Mode" item in the "TEST MENU" must be set to
"
Remote Setup".
After this is done, the printer will reset, beep the bell to alert the operator,
and display the message "
Waiting For Remote Setup". The remote
setup file may now be sent to the printer.
After the printer receives the remote setup file (without error), all specified
configuration changes will be made, the "
Test Mode" item will revert back
to "
Off", and the printer will reset. When this reset is complete, the printer
will be ready for normal interaction with the host system.
The available heading lines, and item setup lines, are documented below.
Note that all the legal values are shown for each item, but in use only one
value may be supplied in the setup file. An example file follows these
definitions.