SOLENOID OPERATED RD5000 DIRECTIONAL CONTROL VALVE
The Solenoid Operated RD5000 Directional Control Valve allows remote electrical on-off or manual control. This
feature can be installed on the RD5100, RD5200, or RD5300. It can be installed on one or all spools of the RD5200 or
RD5300. This option can be purchased as kits and installed by customer. Complete valves are available special order
only (min. qty. 25) Consult your sales representative.
SPECIFICATIONS
MAXIMUM PRESSURE ...............................3000 PSI
MAXIMUM TANK PRESSURE .......................150 PSI
MAXIMUM FLOW .......................................... 25 GPM
MINIMUM FILTRATION .......................... 10 MICRON
MAXIMUM OPERATING TEMPERATURE .......180
0
F
The Solenoid Operated RD5000 contains two, 3 way-2
position solenoid cartridge valves and a pilot operated
piston attached to the main control spool. When both
solenoids are de-energized both sides of the pilot piston
are open to tank pressure and the spool remains spring
centered. When solenoid A is energized, pilot pressure
is applied to one side of the pilot piston causing the
spool to shift from the neutral position to work port A.
When solenoid “B” is energized, pilot pressure is applied
to the other side of the pilot piston causing the spool to
shift to work port “B”. In cases where the pilot pressure
is provided by the inlet line or #4 SAE port on valve, a
“Pressure Build-Up Valve” must be installed in the outlet
port. Two versions of the pressure build-up valve are
offered. The open center pressure build-up valve and
the power beyond pressure build-up valve. Both ver-
sions supply 150-200 PSI pilot pressure to the sole-
noid actuator. When remote pilot is used, the pressure
build-up is not required. Because the valve is internally
piloted, overcenter or light loads can be a problem. The
inlet pressure must be at least 200 psi during operation.
Restrictors can be added to eliminate this problem.
DESCRIPTION PART NUMBER
PRES, BUILD-UP CART. OPEN CENTER 660312012
PRES. BUILD-UP POWER BEYOND CART (#12 SAE) 660312014
12 VDC LEAD WIRE COIL 671302003
12 VDC DOUBLE SPADE COIL 671322004
12 VDC WEATHER PACK 671302013
12 VDC DIN 43650 COIL 671302002
24 VDC LEAD WIRE COIL 671302007
24 VDC DOUBLE SPADE COIL 671322008
24 VDC DIN 43650 COIL 671302006
120 VAC CONDUIT COIL 671302009
120 VAC DIN 43650 COIL 671302010
ITEM QTY PART NUMBER DESCRIPTION
1 1 660150030 BASE ACTUATOR KIT
2 2 SEE CHART SOLENOID COIL
3 1 660150037 END MANIFOLD KIT
4 1 660150033 MID SECTION MANIFOLD KIT
5 1 660150035 MANIFOLD TUBE KIT (SHORT)
6 1 660150036 MANIFOLD TUBE KIT (LONG)
7 1 660150046 PRES. RED. MAN. KIT (MULTI-SPOOL)
8 1 660150047 PRES. RED. MAN. KIT (SINGLE-SPOOL)
9 1 SEE CHART PRES. BUILD-UP CART.
BUILD-UP CART.
PRESSURE
REDUCING
CARTRIDGE
DRAIN TO TANK
PILOT(300 PSI MAX)
SOLENOID B
SOLENOID A
IN
OUT
CD
1
2
3
5
7
9
PRESSURE BUILD-UP CART.
EXTERNAL PILOT FROM #4 SAE PORT
IN VALVE. SPECIAL ORDER ONLY
CONSULT SALES REPRESENTATIVE.
EXTERNAL PILOT FROM INLET
LINE OR REMOTE SOURCE.
PRESSURE REDUCING CARTRIDGE
A SOLENOID
B SOLENOID
HCI-PRINCE
B
IN
A
OUT
BYD