Specifications
40 PROGRAMMING MANUAL 516307 C PUBLICATION DATE 31 JAN 2008.DOC
E35
Wrong Softw
Wrong software
version
Don’t start New software version
E36
Too Hot End
At end cycle, temp.
above 78°C
Warning + Extra
Cooldown Time
End cycle
E37
Too Hot Safety
Temp. much too
high (risk of burn !)
Major Alarm + Extra
Cooldown Time
Whole cycle
E38
Lint Door Switch
Open Lint Door
Switch while cycle is
running.
Drying Cycle Interupted Whole cycle
E41
Service Due
Service Due
Warning
For Info only
Open door = reset
End cycle
E42
Connection No Network
Connection
For Info only Data Transfer
Networking
E99
General memory
and software Err
General memory
and software Err
Heating Off, Full Stop at
safe temperature
Any time
E150
-
E165
Memory Err
Memory Error Full stop + safety time Any time
E170
-
E199
Softw Err
Software Error Full stop + safety time Any time
9.8. EXPLANATION ERROR MESSAGES
For each failure message diagnostics are added.
IMPORTANT!
TECHNICAL INTERVENTION ON THE DRYER IS ONLY FOR QUALIFIED TECHNICIANS WITH
SUFFICIENT TECHNICAL KNOWLEDGE OF THE EASY CONTROL DRYER MACHINE.
FAILURE 1 : HEATING SAFETY 1
Failure 1 occurs when the electronic timer detects that the heating safety located at the air outlet has
opened it’s NC contact. (NC thermal contact) (failure 1 can only occur when the drying cycle is running).
A skilled and experienced technician must examine the heating-and air outlet system before the machine
is put in operation again.
DIAGNOSE:
1. Check the air outlet system. If the air flow is not sufficient, adjust the air
outlet system.
2. Check the temperature sensor. If the temperature sensor is not measuring
correctly, replace the temperature sensor.
3. Check the heating system. If the heating system is broken repair, replace
the heating system.
4. Check the heating contactor (valve) If the heating contactor (valve) is not functional
repair or replace the component.
5. Check the wiring. If the wiring is damaged, repair the wiring.
6. If the heating safety is not closing within 15
minutes.
The heating safety will be probably broken and
must be replaced.
7. Check the output relay that controls the
heating system.
If the output relay is not functional, replace the
electronic card.