Specifications
516307 C PUBLICATION DATE 31 JAN 2008.DOC PROGRAMMING MANUAL 39
IMPORTANT:
FAULT 35 CAN ONLY BE ERASED BY SWITCHING OFF AND ON THE POWER.
9.7. OVERVIEW
N° Failure
message
Failure Action Fault occurrence
E1
Heating Safety 1
Heated air too hot Heating Off, Continue Whole cycle
E2
Heating Safety 2
Heater too hot Heating Off, Continue Whole cycle
E5
Motor Thermic
Motor Security Trips
Heating & Motor Off,
Continue
Whole cycle
E6
Fan Motor
Thermic
Fan Motor Security
Trips
Heating & Fan Off,
Continue
Whole cycle
E7 Drum Motort
Thermic
Drum Motor
Security Trips
Heating & Motor Off,
Continue
Whole cycle
E8
Air flow switch
Open at Startup
Air flow switch at
startup
Heating Off, Continue At Start Up
E9
Air flow switch
Open after
Startup
Air flow switch after
startup
Heating Off, Continue Whole Cycle after Start Up
E10
Air flow switch
Closed
Air flow switch
failure before startup
Don’t start At Start Up
E11
Fault Cooldown
No temperature
drop at cooldown
Heating Off, Continue At Cooldown sequence
E12
No Reheating
Heating not
restarted
Heating Off, Continue At Heating sequence
E13
No Heating
Heating failure Heating Off, Continue At Heating sequence
E15
Too Hot
Too Hot
Heating Off, Full Stop at
safe temperature
At Heating sequence
E16
Coin Blocking 1
Coin Detector 1
Blocked
Continue + Don't start Any time
E17
Coin Blocking 2
Coin Detector 2
Blocked
Continue + Don't start Any time
E18
Too Hot Safety
Temp. much too
high (risk of burn !)
Major Alarm Before Start Up
E19
Defective
Temperature
sensor 1
Value out of range
(Heating Off, Continue)
+ Don’t start
Before Start Up
E20
Defective
Temperature
sensor 2
Value out of range
(Heating Off, Continue)
+ Don’t start
Before Start Up
E22
Ignition Error at
Start up
Ignition fails 3 times Heating Off, Continue At Start Up
E23
Ignition Error
after Start up
Ignition fails 3 times Heating Off, Continue Whole cycle
E24
Ignition Error
Failure
Wrong Ignition Error
Signal
Heating Off, Continue No Heating
E25
No Humidity
Sensor
Humidity Sensor not
connected
Continue, for info only
saved in Err log.
Whole cycle
E26
No Humidity
Sensor Cap
Cap Humidity
Sensor missing
Continue, for info only
saved in Err log.
Whole cycle
E27
No Humidity
Reduction
Time out no
reduction humidity
value.
Heating Off, Full Stop at
safe temperature
Whole cycle
E28
Lint Filter
Lint Filter has not
been opened for 40
cycles.
For info only saved in
Err log.
At Start Up