Specifications

10 PROGRAMMING MANUAL 516307 C PUBLICATION DATE 31 JAN 2008.DOC
ct1 : cooldown time program 1
ct2 : cooldown time program 2
ct3 : cooldown time program 3
Time can be set between 0 – 30 Minutes.
Defaults : ct1 = 5 Minutes
ct2 = 4 Minutes
ct3 = 3 Minutes
Cooldown Ratio
The purpose of the „Cooldown Ratio“ function is to control how quickly the temperature in the dryer
should decrease in function of time at the Cooldown Sequence.
cr1 : Cooldown Ratio program 1
cr2 : Cooldown Ratio program 2
cr3 : Cooldown Ratio program 3
The Cooldown Ratio can be set between 0 – 5°C/min.
Defaults : cr1 = 0°C/min
cr2 = 0°C/min
cr3 = 0°C/min
In case cr1, 2, 3 = 0°C/min, the „Cooldown Ratio“ function is switched OFF.