Specifications

516307 C PUBLICATION DATE 31 JAN 2008.DOC PROGRAMMING MANUAL 9
Drying Time
ONLY FOR OPL MACHINES.
The preprogrammed time for drying at the drying process.
dt1 : drying time program 1
dt2 : drying time program 2
dt3 : drying time program 3
The drying time can be set between 0 – 99 minutes.
Defaults : dt1 = 35 minutes
dt2 = 35 minutes
dt3 = 35 minutes
HUMIDITY CONTROL FUNCTION
Residual Humidity Value Humidity Control
ONLY FOR OPL MACHINES AND MACHINES CONNECTED TO CENTRAL PAYMENT SYSTEM
WITH SELECTION HUMIDITY CONTROL. „Hum“=„on“ in „t-Menu“.
„rH1“, „rH2“, „rH3“ MENU ITEM IS ONLY VISIBLE WHEN DRYING TIME „DT1“, „DT2“, „DT3“, HAS
BEEN PUT ON 0 MINUTES.
The Target value that corresponds with the % value residual Humidity linen.
rH1 : Desired Residual Humidity program 1
rH2 : Desired Residual Humidity program 2
rH3 : Desired Residual Humidity program 3
The Desired Residual Humidity can be set between 0 – 30 %.
Defaults : rH1 = 5%
rH2 = 5%
rH3 = 5%
After an extraction sequence at high speed in a washing machine, the residual humidity of the
linen is about 70 à 50 %.
At the drying process 30 % is still humid, while 0 % is bone dry (and should be avoided for
certain fabrics)
COOLDOWN CONTROL FUNCTION
Cooldown Time
- A Cooldown process is started after the drying process.
- The purpose is to reduce the temperature of the linen at the end of the drying process.