Installation Guide
938 Quail
Street
Lakewood, CO
80215
primuswindpower.com
Pg.4/5
PWP Wind Control Panel Manual
2
-ARAC-103
START UP:
Remove the mechanical tie off of the wind turbine. Turn the POWER switch to the ON position
and the RUN-STOP switch to the RUN position. If there is sufficient wind present, the wind turbine
should begin turning and current should be displayed by the Ammeter. However, if the battery
bank is fully charged, the wind turbine will not rotate. Please see the wind turbine instruction
manual for more information.
Warning
Set the wind turbine RUN-STOP switch to the STOP position prior to switching POWER switch
off or on.
In order for the wind turbine to be operational, the POWER switch must be in the ON position.
When wind is available, this will allow the wind turbine to begin charging the battery bank.
Leaving the circuit breaker “on” and wind circuits active will deplete only a minor amount of
energy from your battery during non-energy producing periods and should not be of concern. The
wind system works in harmony together with other energy producing systems on board such
as solar PV, alternator or AC powered battery charger and therefore it is not necessary to turn “off”
the wind circuit breaker when these are active. The wind turbine monitors battery charge condition
and controls the energy into the battery bank and will not overcharge the batteries should they
become fully charged.
Note
It is strongly recommended the installer/user read the turbine operating manual prior to powering
up the PWP Wind Control panel and related equipment. Adjustments may be necessary based on
the type of batteries in the system and other optional features which may be needed for your
particular installation.
Technical questions and support is available during our normal business hours. Call: 303-242-5820
Mon-Fri 8-5 pm MST