AIR WIND TURBINE TROUBLE SHOOTING
ON TOWER TROUBLE SHOOTING:
With the turbine on the tower, observe the behavior of the turbine dur-
ing dierent states of the stop switch. On a moderate to strong wind day
(winds 15 mph or greater):
1.) Place the stop switch in the STOP posion (or RED and BLACK wires
disconnected from the baery and crossed), the turbine should spin ap-
proximately 2 revoluons per second in moderate to high winds. If the
turbine spins at a signicantly higher rate than that, it is likely an electri-
cal connecon is not secure or is corroded.
2.) Place the stop switch in the OPEN posion (or wires disconnected
from the baery), the turbine should repeatedly start up and shut down
roughly every 30 seconds. If the turbine does this with the stop switch in
any posion, the turbine is not likely electrically connected to the baery
bank.
3.) Place the stop switch in the RUN posion (or breaker turned on), the
LED should blink twice (the duraon of the blinks is dependent on the
code revision for that turbine). The turbine will begin spinning up with
sucient wind and the LED should come on solid (and stay on solid) if
RPM are above 450 and current output should begin. If the turbine does
not spin up and the LED is blinking, it could be that the turbine is in
baery regulaon (i.e. baery voltage is higher than the potenometer
set point, in which case the turbine is behaving appropriately).
NOTE: If the turbine spins roughly two revoluons per second in any
posion of the stop switch (i.e. no change in behavior between dierent
posions of the stop switch), the circuit card (or possibly the stator) is
likely compromised.
4.) With the turbine spinning and the LED on solid, monitor current output
(or baery voltage) as the wind resource uctuates. If monitoring baery
voltage, disconnect all loads (if praccal) to insure the turbine is charging
the baery. If the turbine shuts down (i.e. blades come to a near stop) at
mes you would not expect, note the LED acvity during those mes. Also
note if the shut-down duraon is consistent.
BENCH TESTS:
If the turbine fails the on tower test (s), the next step is the bench tests
below. The bench tests remove the balance of system wiring as a variable.
TEST 1 Stand Alone Test
1.) Remove the blade/hub assembly from the turbine and place in a safe
locaon. Replace the rotor hub nut on the rotor sha.
2.) With the Air turbine completely disconnected and removed from the
baery or any other connecon, Aempt to quickly spin the rotor sha
with your ngers while connecng and disconnecng the red and black
wires (turbine must not be connected to baeries). A second person may
be helpful to perform this test.
3.) With the red and black wires connected to each other, the sha should
be more dicult to turn. With the yaw wires disconnected it should spin
freely. Spinning the sha quickly makes this dierence easier to detect. If
these condions do not exist, contact your turbine dealer or Primus Wind
Power.
IMPORTANT: it is recommended to “Power Cycle” your turbine as a rst step in troubleshoong process. Power your turbine OFF (wait 5 min),
then ON, look for two LED blinks. This process will reset the electronic control circuit and verify the turbine is receiving power.