Installation manual

-78-
10.9.2: Restore Reporting
For each event group, you can determine whether restore messages shall be sent.
To enable/disable restore reporting for an event group.
1. From the Programming menu, select Communications, Event Options [955].
2. Select an event group.
3. From the event group’s sub-menu, select Report Restore [#2].
4. Select Enabled or Disabled.
10.9.3: Two-Way Audio
For Burglary, Fire and Medical event groups, there is an additional option that enables
Two-Way Audio for that event group – see 5.2.2: TWA Alarm Reporting.
To enable/disable Two-Way Audio for an event group:
1. From the Programming menu, select Communications, Event Options [955].
2. Select an Event Group (Burglary, Fire or Medical).
3. Select TWA [#3].
4. Select Enabled or Disabled.
10.10: Vocal Message Dialer Event Options
Events reported using the Vocal Message Dialer are divided into event groups that
correspond with the pre-recorded event messages. This allows you to enable or disable
the Vocal Message feature for a specific group of events. For further information on this
feature, see 10.3: Vocal Message Dialer.
The vocal message event groups and their associated system events are as follows:
Burglary [#1]
o Alarm from Zone (excluding Gas and Environmental zones)
o Zone Tamper
o Tamper
o Duress
Fire [#2]
o Zone Fire Alarm
o User Activated Fire Alarm
Panic [#3]
o Zone Panic Alarm
o User Activated Panic Alarm
Medical [#4]
o Zone Medical Alarm
o User Activated Medical Alarm
o No Motion
System Trouble [#5]
o Battery Low
o Transmitter Low Battery
o AC Loss
o Media Loss
o Device Trouble
o Communication Trouble