Installation manual

-6-
1.2: Specifications
General
Zones: 32 wireless zones (1 transmitter per zone), 1 hardwire zone (Zone 33)
Wireless Keyfobs: 19 (Controlled or Non-controlled)
Wireless Keypads: 4
Hardwire LCD Keypads: 2 (INFINITE-KPD/L), 3 (INFINITE-KPD/S)
Repeaters: 4
Smartkeys (future option): 16 (Controlled or Non-controlled)
Wireless Siren: 1 (1-way or 2-way)
User Codes: 32
Arming Methods: Full, Part or Perimeter
Event Log: 256 event capacity, time and date stamped
Communications
Central Station Event Reporting Accounts: 3 (8-digit account number)
Vocal Message Accounts: 3
Telephone Numbers: 3 regular, 3 Vocal Message, RP Callback and Service Call
(16-digits each)
Communication Interface Options: PSTN or GSM (optional expansion module required)
Home Automation
Control Medium: Power-line carrier
Protocol: X10
HA Units: 16 individually addressed
Receiver
Type: Super-heterodyne, fixed frequency
Frequency: 868.35, 433.92
or 418MHz FM
Data Encryption: SecuriCode™
Electrical
Power Input: 230VAC, 50Hz
Backup Battery Pack: 7.2V/1.5Ah
(6 x 1.2V Ni-MH rechargeable cells, size AA)
Fuse Ratings:
63mA/250V (AC protection fuse),
1A/250V (battery protection fuse)
PGM Relay Output Contact Rating: 100mA
(max. load)
Built-in Siren: 105dB or 85dB
Tamper Switch: N.C.
Operating Temperature: 0-60°C
1.3: System Overview
The infinite prime is a full-featured wireless control system that is expected to provide a
solution to the needs of most residential installations. This system has been developed
based upon a design concept geared towards easy installation and use. With this in mind,
the user interface is based on a simple, menu-driven model that suits the essential
requirements of both the user and installer alike. You can program the infinite prime on-site
using the on-board LCD keypad or off-site via a PC using the up/downloading software.
Power connection to the unit should
be according to the national electrical
code for permanent installation.
The power supply should be fed from a readily
accessible disconnect device.
If the unit is permanently wired to the mains
power, use a 2-pole disconnect device (15A
max.) and the wires should be min. 0.75mm
2
in a conduit of at least 16mm.
If the mains power is connected with a plug,
the plug should be indicated as the
disconnecting device and the socket shall be
max. 2m from the control panel.
Batteries shall be provided by a distributor and
replaced by authorized service personnel.
The backup battery pack should be
replaced every five years.
Batteries should be stored in a cool, dry place.
!