Installation manual

-47-
7.6.1: Zone Type
The zone type defines the type of alarm the system generates when the sensor is tripped.
To program a zone type:
1. From the Programming menu, select Devices, Zones [911].
2. Select the sensor you want to program.
3. From the sensor’s sub-menu, select Zone Type [#02].
4. Select one of the following zone types:
Normal
Entry/Exit
Follower
Panic
Medical
Fire
24H
24Hr-X (future option)
Gas
Flood
Environmental
No Motion
Not Used
For a detailed explanation on the function of each zone type, see Appendix D:
Zone Types
7.6.2: Arm Set
The Arm Set option allows you to define the arming methods in which the zone is included.
To program the Arm Set option:
1. From the Programming menu, select Devices, Zones [911].
2. Select the sensor you want to program.
3. From the zone’s sub-menu, select Arm Set [#03]; the zone’s current
Arm Set setting is displayed.
Arm Set Description
1 (F) The zone is included in Full arming.
2 (P) The zone is included in Part arming.
3 (PE) The zone is included in Perimeter arming.
Table 7.1 Arm Set Options
4. Use the keys 1, 2 and 3 to toggle the current setting.
5. Press when the desired setting is displayed.
,
It is not necessary to program this option for Panic, Medical, Fire, 24Hr, Gas, Flood and
Environmental zones.
7.6.3: Bell
Each zone can be programmed to activate the siren when triggered or to generate a
silent alarm where only a message is sent to the central station.
To program the Bell option:
1. From the Programming menu, select Devices, Zones [911].
2. Select the zone you want to program.
3. From the zone’s sub-menu, select Bell [#05]; the zone’s current Bell
setting is displayed.
4. Select either Enabled or Disabled.
,
Fire zones always activate the siren regardless of what is programmed for this option.
If the bell is disabled for Panic zones, this also disables all forms of alarm indication from
the on-board keypad in the event of a Panic alarm.