Installation manual
-101-
,
Each time the sensor generates an alarm, it also goes into Test mode for one minute.
3. Hold the tester near the surface of the glass and aim the tester at the
EL-2606. If drapes or blinds are present, test with the hand-held tester
behind the closed drapes or blinds.
4. Hold down the test button. When the LED on the sensor goes solid
momentarily, the glass is within detection range.
5. If the LED does not go solid, but simply continues blinking, re-position the
sensor closer to the protected windows and retest. This may require
adding additional sensors in order to achieve adequate coverage. It is very
rare that the sensor will not activate within its stated range of coverage. In
this case check the battery in the hand-held tester. A new tester battery is
likely to restore the range.
6. Test mode automatically terminates approximately one minute after the
last activation of the hand-held tester.
,
Room acoustics can artificially extend the range of a glassbreak sensor. The specified range
of the EL-2606 has been established for worst-case conditions. While the sensor is likely
function at the extended range, it may miss a minimum output break or room acoustics may
be changed at some future time bringing sensor range back into normal 6m conditions. Do
not exceed the rated range of the sensor regardless of what the tester shows!
Hand Clap Test
The Hand Clap test enables you to test the EL-2606 while in Normal mode. This test checks
the sensors power supply, microphone and circuit board.
To perform a Hand Clap test:
Clap your hands loudly under the sensor; the LED flashes twice but an alarm is not generated.
Smoke Detector (EL-2603)
The EL-2603 is a brand-name smoke detector with an integrated Electronics Line
3000 transmitter.
Installation Procedure
The following procedure explains the installation of the EL-2603 wireless smoke detector and
its registration to the receiver. For further information regarding the smoke detector’s location,
test procedures, maintenance and specifications, refer to the manufacturer’s installation
instructions provided with this product.
To install smoke detectors:
1. Open the cover by lifting the opening tab while firmly holding the base with your
other hand.
2. Push the cover backwards to separate the cover from the base.
3. Install a 9V battery into the detector’s battery snap.
4. Insert the Test jumper; the EL-2603 enters Test mode and the LED flashes
every few seconds.
5. From the Programming menu, select Devices, Zones [911].