MSDS

PRODUCT DESC.
SPILLS SHOULD BE ABSORBED OR SCRAPED UP. AVOID WATER CONTAMINATION.
WASTE DISPOSAL
METHOD
EMPTY DEPRESSURIZED CONTAINERS CANNOT BE REUSED. CANS WHICH ARE PRESSURIZED OR CONTAIN LIQUID MUS
T
BE DISPOSED IN A PERMITTED WASTE MANAGEMENT FACILITY. DISPOSAL MUST BE IN ACCORDANCE WITH APPLICABL
E
FEDERAL, STATE AND LOCAL REGULATIONS. INCINERATION EQUIPMENT SHOULD BE CAPABLE OF HANDLING LARGE
VOLUMES OF DENSE BLACK SMOKE AND WITHSTAND THE CORROSIVE EFFECTS OF ACID CASES. THESE MATERIALS
ARE NOT CONSIDERED HAZARDOUS WASTE UNDER TITLE 40, CFR PART 261 (HAZARDOUS WASTES UNDER THE
CONSERVATION RECOVERY ACT), REFERENCE SECTIONS 261.31, .32, .33(E) AND .33(F). THEY DO NOT HAVE THE
CHARACTERISTICS OF A HAZARDOUS MATERIAL AS DEFINED UNDER SECTIONS 261.21, .22, .23, AND .24.
FLAMMABLE LIMITS
(
% BY VOLUME
)
LEL UEL
IN AIR
FLASH POINT
LEVEL 3
AUTOIGNITION TEMP
NA
SHEET 3 OF 4
PRODUCT NAME
MSDS DATE
LUBRICANT
0
RZ-50
10/17/2011
SECTION 7: REACTIVITY DATA
STABILITY
EXTINGUISHING
MEDIA
SPECIAL FIRE
FIGHTING
PROCEDURES
UNUSUAL FIRE &
EXPLOSION
HAZARDS
STOP GAS FLOW. RECOMMEND USE OF DRY CHEMICAL, CO
2
OR HALOGENATED EXTINGUISHING AGENT.
STOP THE GAS FLOW IMMEDIATELY BEFORE ATTEMPTING TO EXTINGUISH ANY GAS FIRE. ALLOW THE FIRE TO BURN
ITSELF OUT. IF THE GAS SOURCE CANNOT BE SHUT OFF IMMEDIATELY, ALL EQUIPMENT AND SURFACES EXPOSED TO
THE FIRE SHOULD BE COOLED WITH WATER TO PREVENT OVER-HEATING, FLASH-BACKS AND/OR EXPLOSIONS.
CONTROL THE FIRE UNTIL THE GAS SUPPLY CAN BE SHUT OFF. ISOLATE THE "FUEL" SUPPLY FROM FIRE. AVOID
SPRAYING WATER DIRECTLY INTO STORAGE CONTAINERS DUE TO DANGER OF BOILOVER. USE PROPER PROTECTIVE
EQUIPMENT AND FRESH AIR RESPIRATORS WHEN EXPOSURE TO HAZARDOUS CONCENTRATIONS OF TOXIC GASES IS
POSSIBLE.
PRODUCT RELEASES FLAMMABLE VAPORS AT WELL BELOW AMBIENT TEMPERATURES AND READILY FORMS
FLAMMABLE MIXTURES WITH AIR AND WILL BURN IN THE OPEN AND CAN BE EXPLOSIVE IN CONFINED SPACES.
PRODUCT VAPORS ARE INVISIBLE AND HEAVIER THAN AIR AND MAY TRAVEL LONG DISTANCES TO POINTS OF IGNITION.
ALKANE/CHLORINE GAS MIXTURES HAVE PRODUCED EXPLOSIONS.
RZ-50 AEROSOL SPRAY LUBRICANT
PRODUCT CLASS
PTFE POLYMER DRY FILM AEROSOL LUBRICANT
SECTION 6: FIRE AND EXPLOSION DATA
PRODUCT PART NO. RZ 50
MATERIAL SAFETY DATA SHEET (MSDS)
C.A.S. NUMBER
MSDS NUMBER
INCOMPATIBILITY
(MATERIALS TO
AVOID
)
STABLE
MAY REACT WITH STRONG OXIDIZING AGENTS
SECTION 9: SPECIAL PROTECTION INFORMATION
HAZARDOUS
COMBUSTION OR
DECOMP PRODUCTS
DECOMPOSITION MAY PRODUCE CARBON MONOXIDE
CONDITIONS TO
AVOID
DO NOT WELD, HEAT OR DRILL CONTAINER (CAN). RESIDUE MAY IGNITE WITH EXPLOSIVE VIOLENCE IF HEATED
SUFFICIENTLY. SPILLS ON SURFACES MAY CAUSE A SLIPPERY SURFACE.
SECTION 8: SPILL OR LEAK PROCEDURES
ACTIONS TO TAKE
FOR LEAK OR SPILLS
RESPIRATORY
PROTECTION
EYE PROTECTION
SKIN PROTECTION
USE ADEQUATE LEVEL EXHAUST VENTILATION. WHERE CARBON MONOXIDE MAY BE GENERATED, SPECIAL
VENTILATION MAY BE REQUIRED. LOCAL EXHAUST RECOMMENDED WHEN APPROPRIATE TO CONTROL EXPOSURE.
HEALTH STUDIES HAVE SHOWN HYDROCARBONS POSE POTENTIAL HUMAN HEALTH RISKS FOR SOME PEOPLE. AS A
PRECAUTION, EXPOSURE TO LIQUIDS, VAPORS AND FUMES SHOULD BE MINIMIZED. WEAR NIOSH/MSHA APPROVED
RESPIRATORS WHENEVER CONCENTRATION IN AIR MAY EXCEED LIMITS.
WEAR SAFETY GLASSES WITH SIDE SHIELDS OR CHEMICAL GOGGLES
WEAR LONG SLEEVES AND CHEMICAL RESISTANT GLOVES-POLYFLUORINATED POLYETHYLENE HAS BEEN SUGGESTED.
OTHER CLOTHING
OTHER EQUIPMENT
STANDARD WORK CLOTHING. WASH AND DRY CONTAMINATED CLOTHING BEFORE REUSE
PRIME LINE PRODUCTS, INC.
26950 SAN BERNARDINO AVE.
REDLANDS, CA 92374
PH: 909-887-8118
FX: 909-880-2906
Email: info@prime-line-products.com
EMERGENCY #: 909-887-8118