Product Overview

C-534-Q
SPECS
C-534 REPLACEMENT PARTS AND STEMS
ROUGH-IN DIMENSIONS
ID Part No. Description ID Part No. Description
1 See Below Stem Assembly, Contains: 1, 5  
1
” OAL
 
7
8
” OAL  
1
” OAL
 
1
” OAL  
1
” OAL
 
1
” OAL C-108KT-808 Loose Key on Lanyard
 
1
” OAL 3  
 
1
” OAL 4  
 
1
” OAL 5  
 
1
” OAL 6 300-6003 
 
1
” OAL 7 C-534KT-804 Handle Conversion Kit to convert to C-434
 
1
” OAL  
1
5
3
4
7
6
2
**For the old style C-534 Series wall hydrant stems, see C-534 Series retired style spec sheet at PRIER.com.
Furnish and install freezeless model C-534 Commercial Wall Hydrant as manufactured by PRIER Products, Inc. Hydrant shall have automatic draining
capabilities with integral ASSE 1052 approved double check vacuum breaker/backow preventer. Hydrant shall have 3/4” hose connection with freezeless
water ow and self-draining functions. After hydrant is turned in the “o” position, hydrant must be capable of draining even with the hose attached and
under pressure without sprayback. Hydrant shall be constructed of all non-ferrous materials with EPDM sealing mechanisms. Hydrant body must be satin
nickel plated. For stability of operation, hydrant stem shall be secured at the seat end with ACME type threads and at the handle end with the packing
nut. Lockshield must be long enough to ensure operation only with the included operating key. Hydrant must be installed through a 1 1/8” diameter hole
without any custom brick cutting. Operating Key is to be furnished with each hydrant. Hydrant insertion length to be x inches. (Close coupled to 24” in
2” increments.)
Optional: Furnish and install ush-mount hydrant box for each valve. Hydrant box shall be manufactured of stainless steel. Box may be installed separately
and hydrant be insertable and removable from front of the box. Access to the hydrant box shall be provided by the same operating key as the valve.
Hydrant Length 



Hydrant Length 



Rough-In


Rough-In
4515 E. 139th Street Grandview, MO 64030 | (800) 362-9055 | PRIER.com