Service manual


GB
Ne tools for R410A
Nes tools for R410A
Applicable to R22
model
Chages
Gauge manifold
x
As the orking pressure is high ,it is impossible
to measure the orking pressure using
conventional gauges . In order to prevent
any other refrigerant from being charged ,
the port diameters have been changed.
Charge hose
x
In order to increase pessure resisting strength.
hose materials and port sizes have been changed(
to 1 /2 UNF 20 threads per inch).
When puchasing a charge hose,be sure to confirm
the port size.
Electronic balance for
refrigerant charging
As orking pressure is. high and gasification
speed is fat ,it is difficult to read the indicated
value by means of charging cylinder ,as air
bubbles occur.
Torque rench
(nominal dia.1/2,5/8)
x
The size of opposing flare nuts have been
increased ,incidentally,a common rench is
used for nominal diameters 1/4 and 3/8.
Flare tool
(clutch type)
0
By incressing the clamp bar’receiving hole
size , strength of spring in the tool has been
improved.
Gauge for projection
adjustment
_
Used hen flare is made by using conventional
flare tool.
Vacuum pump adapter
0
Connected to conventional vacuum pump,it is
necessary to use an adapter to prevent vacuum
pump oil from floing back into the charge hose ,
The charge hose connecting part has to
ports-one for conventional refrigerant (7/16
UNF 20 theads per inch )and one for R41 OA ,if
the vacuum pump oil (mineral)mixes ith R41 OA
a sludge may occur and damage the equipment.
Gas leakage detector
x
Exclusive for HFC refrigerant
Incid e n t a l l y,th e re f r i g e rant cylindercomes i t h the refrig e r a n t
designation(R410A)and protector coating in the U.S’s ARI specified rose color (Ari
color code; PMS 507).
Also the “charge port and packing for refrigerant cylinderrequires 1/2 UNF 20
theads per inch corresponding to the charge pose’s port size.