Service manual
GB
Timer and sleep
Timer
Remote can set 1-24 hours timer on or timer off.
Air conditioner is running .
If set timer off, air conditioner is continuous running and display timer time, �hen
timer time is end, it shutdo�n air conditioner.
air conditioner is shutdo�n .
If set timer on, air conditioner at �aiting state, it display timer time. �hen timer time
is end, it turn on air conditioner.
�hen it set timer , the timer lamp is light and display set temp.
Sleep
If set sleep, the sleep lamp is light, set temp. and fan speed can be adjust.
Timer and sleep can set together, �hich time is end then perform this function.
Air flow control
Define: flap full open angle is 0°, and full close angle is 125°
Po�er on, flap run to full close position.
Turn off air conditioner, flap run to full close position.
Turn on air conditioner, flap first run to full open position, then run to correspond
position.
Fixed �ind
If turn on air conditioner and set fixed �ind at first po�er on, flap first run to full open
position then stop at 40°position.
If change to fixed �ind from s�ing �ind or natural �ind, the flap stop at current
position and store the position.
S�ing �ind
Flap start position is 20°.
Flap is running bet�een 20°and 85°.
Natural �ind is s�ing t�o cycle and stop 15 seconds, flap is stop at current position at
that moment.
Flap stop at 85°at anti cold �ind or defrost procedure in heating mode.
Flap stop at 85°in first 20 seconds of auto mode.
Flap is drive by step motor.
•
-
-
-
-
•
-
-
•
•
•
•
-
-
•
-
•
•
•
•
•
Full open
Fixed �ind
Full close